Berkley B2ZRKL, B3TRKS General Information, Pump Location, Read and Follow Safety Instructions

Page 2

Safety First

General Information

Pump Location

General Safety

Do not allow pump, piping, or any other system component containing water to freeze. Freezing may damage system, leading to injury or flooding. Allowing pump or system components to freeze will void warranty.

Pump approved liquids only with this pump.

Periodically inspect pump and system components.

Wear safety glasses at all times when working on pumps.

Keep work area clean, uncluttered and properly lighted; store properly all unused tools and equipment.

Keep visitors at a safe distance from the work areas.

READ AND FOLLOW

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see

this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury:

warns about hazards that will cause serious personal injury, death or major property damage if ignored.

warns about hazards that will or can cause serious personal injury, death or

major property damage if ignored.

warns about hazards that will or can cause minor personal injury or property

damage if ignored.

WARNING

Rotating parts. Can catch hands, feet, or clothing.

Stay clear of equipment and keep shields in place while pump is running.

Stop motor or engine before servicing pump.

Read owner’s manual before using equipment.

Electrical Safety

The label NOTICE indicates special instructions which are important but not related to hazards.

Carefully read and follow all safety instructions in this manual and on pump.

Keep safety labels in good condition. Replace missing or damaged safety labels.

LOCATION:

Locate the pump as near to the water source as practical. Make the suction pipe run short and straight with as few pipe fittings as possible to keep total friction loss to a minimum.

Install pump in a clean, dry and well drained location if possible and protect against moisture and adverse

WARNING

Hazardous voltage.

Can shock, burn, or

cause death.

Ground pump before

connecting to power

supply.

Wire motor for correct voltage. See “Electrical” section of this manual and motor nameplate.

Ground motor before connecting to power supply.

Meet National Electrical Code and local codes for all wiring.

Follow wiring instructions in this manual when connecting motor to power lines.

weather conditions. Pump should be located on a level, hard surface to prevent shifting or tipping. Locate to be readily accessible for inspection and maintenance.

Careful attention should be taken to assure that Net Positive Suction Head Available (NPSHA) exceeds Net Positive Suction Head Required (NPSHR) by the pump or reduced performance and severe pump damage may result.

Figure 1, Page 3, illustrates where these terms (NPSHA

/NPSHR) originate, and how to determine if the pumping conditions at which you want to operate meet the proper criteria. When in doubt, consult your nearest Berkeley Professional Dealer.

NOTE: If pump site is 1000 feet above sea level, sub- tract 1.2 feet from the NPSHA equation and an ad- ditional 1.2 feet for each additional 1000 feet of eleva- tion.

Page 2

F00633

Image 2
Contents Self Prime Frame Mounted Centrifugal Pump Pump Location Read and Follow Safety InstructionsGeneral Information LocationPiping Suction PipingDischarge Piping Electrical ConnectionTypical Installations Pump FoundationAlignment of Pump and Motor Shaft Direct Coupling DriveShaft Alignment Course AlignmentAlignment Belt DriveAlignment/Proper Belt Tension TensionElectric Motor / Hydraulic Motor Mounting Hydraulic Motor and AdapterSuction Connection Suction LiftNot Recommended When Flooded Suction Exists PressureWater under Pressure Discharge Connection Align piping to minimize flange stressDo not force alignment that can cause flange stresses Electric Motors Check RotationPriming Engine DrivenPerformance Check Observational MaintenanceLubrication RepackingRemoval Packing Ring ReplacementInstalling New Rings General Pump Care Ordering Replacement Parts Berkeley PumpsSelf Prime Bearing Frame Parts BreakdownTroubleshooting Electrical Drive PumpsProbable Cause Symptom Group Engine Mechanical System Engine Drive PumpsII. Quarterly Inspection Routine InspectionQuarterly Inspection III. Quarterly Inspection IV. Quarterly InspectionMaintenance Warranty General Terms and Conditions

B2XRKS, B2ZRKL, B3TRKS, B4ZRKS specifications

The Berkley B2XRKS, B2ZRKL, B3TRKS, and B4ZRKS are innovative fishing rods designed to enhance the angling experience for both novice and experienced anglers. These rods are renowned for their performance, durability, and advanced technologies, making them stand out in the marketplace.

The B2XRKS model incorporates a lightweight yet robust construction that allows for excellent casting accuracy and control. Made from high-quality materials, this rod features a sensitive tip to detect even the slightest nibble, enhancing the chances of a successful catch. The ergonomic handle provides comfort during long fishing sessions, minimizing fatigue and improving grip.

Berkley's B2ZRKL is tailored specifically for versatility in various fishing scenarios. Its medium to heavy power rating accommodates different fishing techniques, from bass to trout. The rod's backbone offers enough strength to handle larger fish, while still maintaining the sensitivity required for finesse presentations. This model is equipped with high-performance guides that promote smoother line flow, reducing friction and enhancing casting distance.

The B3TRKS model takes innovation a step further by integrating cutting-edge anti-tangle technology. This feature dramatically reduces the chances of line tangles, allowing anglers to focus solely on their fishing. Additionally, the B3TRKS is designed with a seamless blank construction, enhancing durability and performance. The rod’s lightweight design does not compromise its strength, making it ideal for extended use.

Lastly, the B4ZRKS model stands out for its advanced construction methodologies. Utilizing a unique blend of materials, this rod achieves an optimal balance of weight and power. It features a precision-molded tip, providing unparalleled sensitivity and responsiveness. The B4ZRKS also benefits from a specialized grip system that ensures a secure hold even in wet conditions, enhancing performance during challenging weather.

In summary, the Berkley B2XRKS, B2ZRKL, B3TRKS, and B4ZRKS rods offer a range of features that cater to various fishing styles and preferences. Their incorporation of advanced technologies and premium materials ensures that anglers can rely on these rods for both performance and durability. Whether casting for bass or reeling in trout, these rods are designed to maximize the fishing experience, making them an excellent choice for any angler looking to improve their craft.