Troubleshooting |
|
|
| WARNING: | |
|
| |
|
| To reduce the risk of fire, electric |
|
| shock or injury, unplug from the |
|
| outlet before servicing. |
|
|
|
Heat indicator light does not illuminate |
|
Possible Causes | Remedies |
1.The heater switch is not turned on.
2.The machine power switch is not turned on.
1.Turn on the heater switch located on side of unit.
2.Both switches must be on
to activate the heat indicator light.
Reduced spray OR no spray
Possible cause
1.Bladder may be empty.
2.
3.Pump may have lost prime.
4.The pump belt may be broken.
A.
B.
Remedies
1.Turn power switch off; Refill bladder with clean hot tap water and formula.
2.Turn power switch off; remove tank and reseat tanks.
3.Turn power switch off; after 1 minute turn on and depress spray release trigger.
4.Turn power switch off and unplug
from the outlet. To check if a pump belt has broken, you will need a flat head screwdriver.
A.Insert the blade end into the slot of the belt access door to release. Examine the belt for breakage. You should be able to see the pump belt looped around the motor shaft. If it is broken or missing, please refer to Replacement Parts on page 18.
Areplacement belt may be ordered at www.bissell.com or by calling BISSELL Consumer Services at
will accompany the replacement belt.
B.When replacing belt access door be sure to line up slots of belt access door with slots in machine, slide door into place and snap shut.
Slots Pump Belt
16 w w w . b i s s e l l . c o m
8 0 0 . 2 3 7 . 7 6 9 1
6/26/08 2:23:13 PM |