Clarke L26 manual Maintenance, Do These Procedures When You End Your Work

Page 20

Maintenance

Do These Procedures When You End Your Work

1.Drain the solution tank (Figure 25) and the recovery tank (Figure 26). To drain the tanks , follow this procedure:

a.Turn the key switch “OFF”.

b.Remove the drain hose from the back of the machine.

c.Put the end of the hose over a drain or bucket.

d.Recovery Tank:

1.) Turn the valve handle to the left. Pull the handle out to open the drain (Figure 27).

NOTE: Have the opening in the side of the valve away from you when you open the valve.

2.) To open the valve completely, turn the handle to the right. Pull the handle out of valve (Figure 28).

Solution Tank:

When hose is lowered to water level, water will flow.

2.Flush the tanks. To flush the tanks, put clean water in the tank through the opening on top of the tank.

3.If a tank or drain hose has an obstruction, use a pressure water hose to flush the tank or hose. Put the water hose into the drain hose.

4.Leave the tanks and the recovery drain valve open to dry in the air.

5.Check the squeegee blade. Use a cloth to clean the squeegee blade. If the squeegee blade is damaged or worn, turn or replace the blade.

6.Check and clean the solution lid gasket. Use a mild cleaning solution and rinse the parts in clean water.

7. The debris tray needs to be emptied regulary to prevent over flow. To remove the debris tray from the machine, follow this procedure (see figure 29):

a.Go to the left side of the machine, to the rear of the cylindrical brush head.

b.Grab the end of the tray with the left hand and the center of the tray with the right hand.

c.Lift center of tray with right hand and slide tray out with left hand.

d.Empty tray and clean before sliding tray back in. Make sure upper and lower slides are engaged.

Figure 25

Figure 26

Figure 27

Figure 28

Figure 29

Page -20-

CLARKE TECHNOLOGY Operator's Manual -Encore L26 Cylindrical

Image 20
Contents Manual Read this BookTable of Contents Avertissement Advertencia Severe bodily injury or death. Read and observe all DangerClarke Technology Operators Manual -Encore L26 Cylindrical Introduction & Machine Specifications Introduction & Machine SpecificationsProcedures For Transporting Figure #1Procedures For Transpoting Symbols Used on Encore L26 Cylindrical Symbols Used on Encore L26 Cylindrical Hour Meter Not Illustrated Option Key Switch See , Item aMachine Control Panel Machine Controls and Features Parking Brake Optional, See FigureHow To Prepare the Machine For Operation How To Install The BatteriesBattery Maintenance How To Charge The Batteries How To Change or Rotate Brushes How To Fill The Solution Tank How To Operate The MachineHow To Operate The Squeegee How To Clean a Floor Operating The MachineHow To Clean a Very Dirty Floor Do These Procedures When You Begin Your Work Period MaintenanceThese Maintenance Procedures Must Be Done Every Day Maintenance Do These Procedures When You End Your WorkMaintenance Procedures To Be Done Every Week Distilled Water onlyMaintenance For The Squeegee How To Adjust The Squeegee Adjusting Squeegee TiltAdjusting Squeegee Blades How to Center or Offset the Brush HeadHow to Level the Cylindrical Brush Head Clarke Technology Encore L26 Cylindrical Accessories 3/02 Squeegee Blades Description AssemblyDescription Brushes Size Description Used ForClarke Technology Operators Manual -Encore L26 Cylindrical Encore HOW to Correct Problems in the Machine Cause Action There is no solution flowProblem Cause Action Page Alto Product Support Branches Clarke Technology Limited U.S. Warranty Battery WarrantyAlways use genuine ClarkeTechnology Parts for repair Highway Springdale, Arkansas