Kenmore 625.385200 manual Leak Test, Restart the Water Heater, Single Bypass Valve, Valve Bypass

Page 12

Installation

LEAK TEST

To check for leaks, complete the following steps:

1. Fully open two nearby cold water faucets down- stream from the softener.

2. Observe steady weater flow from both open faucets. 3 After about three minutes, open a hot water faucet for about one minute, or until all air is expelled, then close.

4. Close both cold water faucets.

5. Check your plumbing work for leaks, and fix right away if any are found. Be sure to observe previous caution notes.

NOTE: If this procedure is performed on a new softener, water coming from the taps may initially be dis- colored. This normally occurs the first time water runs through the resin bed. The discol- ored water is not harmful, and the discoloration will not last more than a few minutes.

RESTART THE WATER HEATER

Turn on the gas (or electric) supply to the water heater and light the pilot.

YOUR PLUMBING INSTALLATION AND ELECTRICAL WORK ARE NOW COMPLETE.

SINGLE BYPASS VALVE

Pull stem outward

for Service

Push inward for Bypass

Figure 13

3-VALVE BYPASS

FOR SERVICE

 

Bypass

Close bypass valve.

 

Valve

Open inlet & outlet

Outlet

 

valves.

Inlet

Valve

FOR BYPASS

 

Valve

Open bypass valve.

 

 

Close inlet & outlet

 

 

valves.

 

 

 

 

Figure 14

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com

12

Image 12
Contents Hybrid Water Softener Warranty Warranty on Kenmore Elite Hybrid Water SoftenerTable of Contents Safety GuidesSpecifications & Performance Claims SpecificationsDimensions Performance ClaimsBarium 10 ±10% mg/L Mg/L Radium 226/228 25 pCi/L PCi/L Chlorine ±10% mg/L 50%Plan Your Installation Packing ListLine Outside Faucet Hard waterInstallation Check Your Water Pressure Before InstallingAlternate Bypass Valve Installation Bypass Valve or Plastic ClipBypass valve with a wet rag Ring Incoming Hard Water Connect the Valve Drain Hose Install Covers Connect to Electrical PowerMetal Pipe Grounding Rinse OUT Carbon FinesLeak Test Restart the Water HeaterSingle Bypass Valve Valve BypassProgramming the Softener Blue LightProgram the Softener SET Present Time of DAYSET Water Hardness Number SET Salt TypeFlushing the System Adding Salt to the Storage TankAdding Salt to the Storage Tank Water Softening Salt with Iron Removing AdditivesController Features What Your Hybrid Water Softener Will DoExtra Recharge Recharge NOWOptional Settings = Salt Efficiency = Clean Feature Salt Monitor SystemPress Select again to display the 12 or 24 hr screen Tank Light Press Select again to display the Recharge Days screenPress Select to return to the normal run time of day screen Tank Light IconRecharge Time Remaining & Valve Position Indicators Water Flow Through the SoftenerProgram Memory Service Information Care of Your Water SoftenerSalt Bridge TenerTroubleshooting Problem Cause CorrectionManually Initiated Electronic Diagnostics Resetting to Factory DefaultsPosition Markers valve in service Wiring Schematic Water Softener Exploded View Softener Parts List Valve Assembly Exploded View Valve Parts List Page For Iowa USE only ModelGet it fixed, at your home or ours