Kenmore 625.385200 manual Manually Initiated Electronic Diagnostics, Resetting to Factory Defaults

Page 23

Service Information

MANUALLY INITIATED ELECTRONIC DIAGNOSTICS

1. To enter diagnostics, press the SELECT button and

 

 

hold for three seconds. The display will change to

Motor

 

show turbine count, valve cycle position, and position

 

switch status (open or closed).

 

 

 

Valve Position Indicator

Position

Sensor

Number of Days since

Switch

Housing

the last Regeneration

 

Turbine

Turbine Count

 

(No Water Flowing)

 

Turbine

Position Switch Indicator (Open)

Figure 41

 

 

Support

TURBINE OPERATION: If no water is flowing through

Valve Outlet

& Shaft

Figure 43

the softener, the turbine indicator displays three zeros.

 

When water is flowing, a 000 to 140 count repeats for

 

 

each gallon of water passing through the turbine. To

= Press and hold the s DOWN button to display the

check for positive operation of the turbine if zeros are

shown, open a nearby soft water faucet and observe

number of regenerations initiated by this controller

the turbine count. If you don’t get a reading in the dis-

since the model code number was entered.

play with faucet open, pull the sensor housing from the

NOTE: If the electronic controller is left in the diagnos-

valve outlet port (see Fig. 43). Pass a small magnet

tic display (or a flashing display when setting

back and forth in front of the sensor. You should get a

times or hardness), the normal time of day dis-

reading in the display. If you get a reading, unhook the

play automatically returns if a button has not

inlet and outlet plumbing and check the turbine for

been pressed for 4 minutes. To return to the

binding.

 

diagnostic display, repeat step 1, above.

POSITION SWITCH STATUS: With the valve in service,

RESETTING TO FACTORY DEFAULTS

or any of the recharge cycle positions, the position

switch indicator will show the switch open.

While the

To reset the electronic controller to its factory default

valve is rotating from one position to another, the posi-

for all settings (time, hardness, etc.):

 

tion switch indicator will show the switch closed. There

1. Press the SELECT button and hold it until the display

is likely a problem if indications vary from this pattern.

 

 

changes twice to show the flashing model code.

Minutes of Cycle (ex-

2. Press the r UP button to display a flashing “SoS”.

ample: Fill) Remaining

 

 

Turbine Count

 

 

(Water Flowing)

 

 

 

Figure 42

 

 

OTHER INFORMATION: While in the diagnostics

 

 

screen, the following information is available and may

 

Figure 44

be beneficial for various reasons. This information is

 

retained by the electronic controller from the first time

3. Press the SELECT button, and the electronic controller

electrical power is applied to the unit.

 

will restart.

 

= Press and hold the r UP button to display the num-

4. Set the present time, hardness, etc., as described on

ber of days this controller has had electrical power

pages 13 & 14.

 

applied.

 

 

 

Questions? Call the Kenmore Water Line 1-800-426-9345 or visit www.kenmorewater.com

23

Image 23
Contents Hybrid Water Softener Warranty on Kenmore Elite Hybrid Water Softener WarrantySafety Guides Table of ContentsSpecifications Specifications & Performance ClaimsChlorine ±10% mg/L 50% DimensionsPerformance Claims Barium 10 ±10% mg/L Mg/L Radium 226/228 25 pCi/L PCi/LPacking List Plan Your InstallationOutside Faucet Hard water LineCheck Your Water Pressure Before Installing InstallationBypass valve with a wet rag Ring Incoming Hard Water Alternate Bypass Valve InstallationBypass Valve or Plastic Clip Connect the Valve Drain Hose Rinse OUT Carbon Fines Install CoversConnect to Electrical Power Metal Pipe GroundingValve Bypass Leak TestRestart the Water Heater Single Bypass ValveSET Present Time of DAY Programming the SoftenerBlue Light Program the SoftenerSET Salt Type SET Water Hardness NumberWater Softening Salt with Iron Removing Additives Flushing the SystemAdding Salt to the Storage Tank Adding Salt to the Storage TankRecharge NOW Controller FeaturesWhat Your Hybrid Water Softener Will Do Extra RechargeSalt Monitor System Optional Settings = Salt Efficiency = Clean FeaturePress Select again to display the 12 or 24 hr screen Tank Light Icon Tank LightPress Select again to display the Recharge Days screen Press Select to return to the normal run time of day screenProgram Memory Recharge Time Remaining & Valve Position IndicatorsWater Flow Through the Softener Tener Service InformationCare of Your Water Softener Salt BridgeProblem Cause Correction TroubleshootingResetting to Factory Defaults Manually Initiated Electronic DiagnosticsPosition Markers valve in service Wiring Schematic Water Softener Exploded View Softener Parts List Valve Assembly Exploded View Valve Parts List Page Model For Iowa USE onlyGet it fixed, at your home or ours