_;_;: SECTION2 _J_,,,,J,_l HOW YOUR WATER SOFTENER WORKS
B. SOFT WATER SERVICE and REGENERATION
AUTOMATIC BYPASS
Dunng the brining, brine rinse and backwash cycles
of regeneration, HARD water goes through the soft- ener valve and to the house pipes. If a faucet is opened, hard water is there for your needs. Howev-
er, you should not use hot water, if possible, because the water heater will refill with hard water. The soft-
ener, as factory programmed, regenerates from 2:00 AM to about 4:00 AM, a time when not much water is used.
If you start your day prior to 4 AM, you may need
to change the recharge starting time. Set the re-
charge time to 12:00 AM or 1:00 AM (page
Then regeneration will start and end that much ear- lier and your water heater will not refill with hard water if a hot faucet is opened.
ELECTRONICS
Two main parts of the softener's electronics are [] a WATER METER, and [] a COMPUTER.
[] WATER
ener valve outlet. As water flows through the meter,
it sends electric pulses to the computer. The com-
puter changes the pulses to a measure in gallons of water.
[] COMPUTER
faceplate timer circuit board. It is programmed to
know the softener's capacity (how many grains of
hardness minerals it will take out of the water before
a regeneration is needed). When starting the soften-
er, page 1- 4, you set it for the grains per gallon (gpg)
hardness | of | the | water. |
|
|
|
|
|
|
| |
To find | a regeneration | pattern | best | for your | needs, | ||||||
the | computer | uses: (1) water usage from the meter, | |||||||||
(2) | hardness | setting, | (3) | softener | capacity, |
| and | (4) | |||
time | since | the | last | regeneration. | The | computer | |||||
always | adjusts | this | pattern | to your water | using | ||||||
habits. | It works | toward | providing | you | with | soft |
water for the longest time and at the most efficient salt usage.
Softening capacity is used as hard water goes
through the softener and hardness minerals are
removed. When the computer determines that only enough capacity remains to provide soft water up to
the next regeneration starting time (2:00 AM, or as
otherwise set) it will schedule a regeneration.
RECHARGE TONIGHT displays until the
regeneration begins. When the regeneration begins,
RECHARGE TONIGHT goes off and *RECHARGE
or RECHARGE TIME REMAINING flashes during the regeneration.
* Note:
If the CLEAN feature is set to ON, a cleaning back- wash (CLEAN and Bkwsh or Rinse flashes in the dis-
play, along with the minutes of the clean cycle re-
maining), precedes the recharge.
Problems, Questions? Call