SECTION 2
HOW YOUR WATER SOFTENER WORKS
2A.FACE PLATE TIMER FEATURES
OPTIONAL SETTINGS± CLEAN FEATURE
WATER FLOW THROUGH THE SOFTENER
MINUTES, MAXIMUM DAYS BETWEEN REGEN- ERATIONS, and 12 / 24 HOUR TIME READINGS:
1.To set 1, 2 or all 3 options, press and hold SELECT for 3 seconds. Then press again until the CLEAN TIME display shows.
MIN |
|
| MIN |
CLEAN | CLEAN | ||
TIME | TIME |
If soft water is in use, the water flow bars continually scroll across the display. The bars scroll slowly when water flow is slow, and move faster as water flow increases. The flow bars do not show when all faucets and water using appliances are off.
8OFF
3
2
1
8OFF
3
2
1
PM
WATER FLOW
no water flow
PM
WATER FLOW
default minutes | example: time set to 3minutes |
CLEAN feature minutes: If you are using this feature (page 7), the length of the extra backwash cycle automatically sets to 7 minutes. However, you can adjust this time from 1 to 15 minutes in length. To change this cycle time, use the UP button to increase the time, or the DOWN button to shorten the time. If no change is desired, continue below.
2.Press SELECT again to show the following RECHARGE display.
|
|
|
|
|
|
|
| DAY | DAY |
|
|
|
|
|
|
|
| ||
RECHARGE | RECHARGE | ||||||||
|
|
|
|
|
|
|
|
|
|
default display | example: set to 4 days maxi- |
| mum between regenerations |
Maximum days between regenerations: The faceplate timer automatically controls regeneration frequency (see page 14). This provides the greatest operating efficiency, and normally the maximum days feature is not needed. If you want to be certain a regeneration will occur within a number of days, use this feature. For example, if your water supply contains iron and you want the softener to regenerate at least once every few days to keep the resin bed clean, set the display as typically shown above. Setting is available from 1 to 15 days by using the UP and DOWN buttons.
3.Press SELECT to show the 12 HOUR display.
Flow bars scroll when soft water is in use.
RECHARGE TIME REMAINING and VALVE
POSITION INDICATORS
One of the valve position indica; | valve |
| recharge | |||||||
tors (Serv, | Fill, Brine, Bkwsh, | position |
| time | ||||||
indicators | remaining | |||||||||
Rinse) | is | displayed while | the |
|
|
|
| |||
|
|
|
|
|
| |||||
softener | is | recharging | (See |
|
|
|
|
|
| |
| 8 OFF |
| Serv |
|
| |||||
| 7 |
| Fill | MIN |
| |||||
*NOTE on page 10 if the CLEAN |
| 6 |
| Brine |
| |||||
| 5 |
| Bkwsh | RECHARGE |
| |||||
| 4 |
|
| |||||||
feature | is | ON). RECHARGE |
|
| Rinse | TIME REMAINING |
| |||
| 3 |
|
|
| ||||||
|
|
|
|
| ||||||
| 2 |
|
|
|
| |||||
flashes in the display and, begin; |
| 1 |
|
|
|
| ||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
ning with Brine, the minutes of recharge remaining before return to service appears in place of the present time. When the valve is moving from one cycle to another, both position indicators are flashing.
PROGRAM MEMORY
If electrical power to the softener goes off, the time display is blank but the face plate timer keeps the correct time for about 6 hours. When electrical power comes on again, you have to reset the present time only if the display is flashing. The HARDNESS and RECHARGE TIME never require resetting unless a change is desired.
Even if the timer is incorrect after a long power outage, the softener works as it should to keep your water soft. However, regenerations may occur at the wrong time of day until you reset the timer to the correct time of day.
12 or 24 hour clock: All time displays are shown in standard clock time (1 to 12 PM; and 1 to 12 AM) at the 12 hr default setting. If military time displays are desired, set to 24 hr by pressing the UP button.
AM
PM
TIME
TIME
ERROR CODE
An error code could appear in the face plate display if a prob; lem occurs in the softener elec; tronics. If you see an error code instead of the present time of day, please call you local Sears
4.Press SELECT to return the present time display.
Service Department for service.
11