Diamond Power Products GXSF27B, GXSF39B, GNSF18Z01, GNSF35Z01 Open a Nearby Soft Water Faucet

Page 17

Turbine Switches

OR

Water

Switch (B)

Meter (A)

 

Service: Manually Initiated Electronic Diagnostics

1 To enter diagnostics, press and hold the SELECT button until (000 – –) shows in the display.

AThe first 3 digits indicate water meter operation as follows:

000 (steady) = soft water not in use…no flow through the meter.

—OPEN A NEARBY SOFT WATER FAUCET—

000 to 199 (continual) = repeats display for each gallon of water passing through the meter.

Motor

Position

 

switch

Sensor

 

housing

 

Turbine

Valve

Turbine

support &

outlet

shaft

If you don’t get a reading in the display, with faucet open, pull the sensor from the valve outlet port. Pass a small magnet back and forth in front of the sensor. You should get a reading in the display. If you get a reading, shut off water supply, unhook the in and out plumbing and check the turbine for binding.

B The letter (P) and dash(es) indicate POSITION switch operation. The letter appearing means the switch is closed; the dash means the switch is open. Use the TOUCH or HOLD (RECHARGE TONIGHT– RECHARGE NOW) button to manually advance the valve into each cycle and check correct switch operation.

CORRECT SWITCH

 

DISPLAYS

VALVE CYCLE STATUS

— Valve in service, fill, brining, backwash or fast rinse position.

— P

Valve rotating from one position to another

C While in this diagnostic screen, the following information is available and may be beneficial for various reasons. This information is retained by the computer from the first time electrical power is applied to the control.

Press and hold the UP button to display the number of days this control has had electrical power

applied.

Press and hold the DOWN button to display the number of regenerations initiated by this control since the SR code number was entered.

2 Press the SELECT button and hold in three seconds until a Service Rating code appears in the display. Repeat this step if the SR code is not displayed.

For correct water softening system operation, the SR number must be SR22 for model GXSF27B, SR31 for model GXSF39B, SR18 for model GNSF18Z and SR35 for model GNSF35Z.

To reset the code, press the UP or DOWN button until the correct number shows.

3 Press SELECT to return to the present time display. If the code was changed, make ALL the timer settings.

NOTE: If the control is left in a diagnostic display or a flashing display when setting times or hardness, present time automatically returns if a button is not pressed within four minutes.

17

Image 17
Contents Water Softening system Two easy ways to register your appliance GE & You, a Service PartnershipSafety Precautions Unpacking and Inspection Installation instructionsImportant Installation Recommendations Tools and Materials Required for Installation Plan How You Will Install the SoftenerWhere to Install the Softener Optional 3-Valve Bypass Installation Illustration Typical Installation IllustrationInstall Bypass Valve Step-by-step installation instructionsProgram the Control SmartWater Softener System Programming the ControlSanitizing Procedures SPECIFICATIONS/DIMENSIONS GNSF18 GXSF27 GNSF35 GXSF39 About the water softener system Breaking a Salt Bridge Cleaning the Nozzle and Venturi Assembly Feature Program Memory Feature Optional Recharge ControlsFeature/Service Automatic Electronic Diagnostics Normal Operation, Control DisplaysERR Service Timer/Softener, Service Checkout ProcedureTo remove an error code 1 Unplug transformer Open a Nearby Soft Water Faucet If the water softening system does not draw brine, check Checking the Salt Storage Level and Refilling Care and cleaning of the water softening systemCleaning Iron Out of the Water Softening System Problem Possible Causes What To Do No soft water Before you call for service…Not using any salt After installation Water softening systemAfter installation Water feels slipperyResin beads showing Is cloudy Error Code on controlUp in drinking water Sink Sounds you might hear Water has air bubblesPage Page We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Parts list 153 Parts catalog Spacer For The Period GE Will Replace GE Water Softening System WarrantyWhat GE Will Not Cover Warrantor General Electric Company. Louisville, KYGE Answer Center Service Telephone Numbers

GXSF27B, GXSF39B, GNSF18Z01, GNSF35Z01 specifications

Diamond Power Products is well-known for its innovative solutions in the field of industrial equipment, and its GNSF35Z01, GNSF18Z01, GXSF39B, and GXSF27B models stand out for their advanced technologies and robust features. Each of these products is designed with a clear focus on enhancing performance, efficiency, and reliability in various industrial applications.

The GNSF35Z01 is notable for its exceptional power output and durability. It is engineered with a high-performance motor that ensures consistent operation even under demanding conditions. One of its key features is its energy-efficient design, which not only reduces operational costs but also minimizes environmental impact. Additionally, this model incorporates advanced cooling technologies to prevent overheating, thereby prolonging its lifespan and ensuring sustained productivity.

Similarly, the GNSF18Z01 is aimed at users who require a compact yet powerful solution. This model excels in versatility, making it suitable for a wide range of tasks. Its lightweight structure enables easy handling, while its robust construction guarantees durability. The GNSF18Z01 also features smart control technologies that optimize its performance, allowing operators to achieve precise results with minimal effort.

On the other hand, the GXSF39B model focuses on high throughput and efficiency. Its innovative design includes enhanced flow management systems that maximize performance during operation. This model is particularly favored in applications where speed and efficiency are critical. The GXSF39B is equipped with user-friendly interfaces, which simplify operation and maintenance, making it an indispensable tool in any industrial setting.

The GXSF27B is another significant addition to Diamond Power’s lineup. It is specially crafted to handle heavy-duty applications with ease. The robust frame and high-quality components ensure that it can withstand rigorous use. Its advanced safety features provide operators with peace of mind, knowing that operational safety is prioritized. This model also embraces modern technologies, such as IoT capabilities, allowing for real-time monitoring and data analysis, which can enhance decision-making processes.

In conclusion, the GNSF35Z01, GNSF18Z01, GXSF39B, and GXSF27B models from Diamond Power Products showcase cutting-edge technologies and exceptional features. These products exemplify the brand's commitment to providing reliable, efficient, and versatile solutions for the industrial sector, enabling businesses to operate at peak performance while meeting their environmental responsibilities. Whether for high efficiency, compact design, or heavy-duty applications, Diamond Power Products delivers equipment that aligns with the evolving needs of modern industries.