American Standard 6065.22X, 6067.22X, 6065.26X Connect Front Panel to, Electrical BOX AC Power

Page 7

7 CONNECT FRONT PANEL TO

ELECTRICAL BOX (AC POWER);

Fig. 10

1. Remove the four COVER SCREWS (1) and COVER

from (2) ELECTRICAL BOX (4). Fig. 10.

2. Pull the CIRCUIT BOARD (3) out from ELECTRICAL

BOX (4). Fig. 10.

3. Knock out lower blank in ELECTRICAL BOX (4) with

flat blade screwdriver. Install from the back of

ELECTRICAL BOX (4) the POWER SUPPLY GROMMET

(8). Fig. 10a.

Fig. 10

1

4

2

3

4. Attach the SAFETY CHAIN (5) from the FRONT

PANEL (6) to the MOUNTING POST (7) as shown.

Feed the Red and Black wires through the back opening

in the ELECTRICAL BOX (4). Fig. 10a.

5. From back of ELECTRICAL BOX (4) remove SPLIT

PLUG (8a) from POWER SUPPLY GROMMET (8). Insert

POWER CORD CONNECTOR (9) through POWER

SUPPLY GROMMET (8). Insert POWER CORD (10) into

SPLIT PLUG (8a). Push SPLIT PLUG (8a) into POWER

SUPPLY GROMMET (8) to seal. Fig. 10b.

6. Insert POWER SUPPLY CONNECTOR (9) into

RECEPTOR (11) on CIRCUIT BOARD (3). Install

CIRCUIT BOARD (3) into ELECTRICAL BOX (4).

Fig. 10b.

Fig. 10a

4

8

KNOCK OUT

BLANK

6

T O P

7

5

BLACK &

RED WIRES

7. Install the SENSOR WIRE GROMMET (15) into the

Fig. 10b

COVER (2) as shown. Remove the SPLIT PLUG (15a)

from SENSOR WIRE GROMMET (15). Insert SENSOR

WIRE CONNECTOR (12) through SENSOR WIRE

GROMMET (15). Insert SENSOR WIRE (13) into SPLIT

PLUG (15a). Push SPLIT PLUG (15a) into SENSOR

WIRE GROMMET (15) to seal. Fig. 10c.

8. Insert SENSOR WIRE CONNECTOR (12) into

CIRCUIT BOARD RECEPTOR (14) slot. Fig. 10c.

9. Replace COVER (2). Tighten COVER SCREWS (1)

firmly.

9

3

4

 

 

8 11

8a 9

10

T O P

7

8

Fig. 10c

12

13

15 15a

2

1

T O P

14

6

M968550 REV. 1.5

 

Image 7
Contents Concealed Flushometer For 1-1/2Top or Back Spud Bowls Installation InstructionsUnpacking InstallationRecommended Tools Fig Roughing-in DimensionsPrior to Installation Following items must be installedFlush OUT Supply Lines Fig Install Electrical BOXAssembly Fig Install Sweat Solder Adapter FigConsult Code for details Install Vacuum Breaker and Flush Connections FigConnect Flush Valve to Piping Fig Install Flush Valve FigInstall the Sensor Wire Grommet 15 into Electrical BOX AC PowerConnect Front Panel to Install Front Panel Fig Connect Front Panel to Electrical BOX DC Power Battery FigConnect Solenoid Wiring and Power Supply Fig Connect Override HOSES, AC & DC Power FigFor AC-VERSION Unit #1Unit #2 Unit #3Remove Front PANEL. For removing front panel Adjust Supply Stop FigSee for instructions Stand outside of sensor detection aera Howto SET Detection Range If RequiredTroubleshooting Flow Charts Selectronic