American Standard 6068.22X Unit #1, Unit #2, Unit #3, For AC-VERSION, Multi HOOK-UP , 15a

Page 10

Fig. 15

Unit #1

 

 

T O P

SENSOR

 

WIRE

6

 

10

7

 

Unit #2

13

T O P

 

SENSOR

 

WIRE

6

 

10

7

 

Unit #3

13

T O P

 

SENSOR

 

WIRE

6

 

10

7

8

12

8

12

8

12FOR AC-VERSION

(MULTI HOOK-UP); Fig. 15, 15a

1. Remove the COVER SCREWS (1) and COVER (2) from each ELECTRICAL BOX (3).

2. See AC Version Electrical Hook-up for Unit #1 of the Multi

hook-up.

3. Install SENSOR WIRE GROMMET (4) and FLUSH VALVE

SENSOR WIRE (5) into the COVER (2) of each unit. Insert

the flush valve sensor wire connector into the CENTER

CIRCUIT BOARD RECEPTOR (6) on each unit. Fig. 15a.

Fig. 15a

Unit #1

SENSOR WIRE

CONNECTOR

 

 

T O P

5

4

6

 

10

 

 

 

 

9

 

 

3

4. Remove the SPLIT PLUG (7a) from the SENSOR WIRE

GROMMET (7) on the left side of each ELECTRICAL BOX (3).

2

7a

5. Take the 10 ft. EXTENSION WIRE (8) from Unit #2 and

insert one end of the EXTENSION WIRE CONNECTOR (9)

through the SENSOR WIRE GROMMET (7) on left side of Unit

#1. Insert EXTENSION WIRE (8) into SPLIT PLUG (7a). Push

SPLIT PLUG (7a) into SENSOR WIRE GROMMET (7) to seal.

Insert EXTENSION WIRE CONNECTOR (9) into LOWER

CIRCUIT BOARD RECEPTOR (10). Fig. 15a.

6. Insert other end of EXTENSION WIRE (8) into SENSOR

WIRE GROMMET (7) on left side of Unit #2. Insert that

EXTENSION WIRE CONNECTOR (9) into the LOWER

CIRCUIT BOARD RECEPTOR (10) of Unit #2. Fig. 15b.

7. On Unit #2 ELECTRICAL BOX (3) remove ROUND

KNOCK-OUT (11) on the bottom of the box by pressing a

flathead screwdriver into the center of the ROUND

KNOCK-OUT (11). Fig 15b.

8. Insert additional SENSOR WIRE GROMMET (12) included

with Unit #2 into the knock-out opening in the bottom of the

ELECTRICAL BOX (3). Take the 10 FT. EXTENSION WIRE

(8) from Unit #3 and insert one end into the SENSOR WIRE

GROMMET (12) in the bottom of the ELECTRICAL BOX (3) of

Unit #2. Insert EXTENSION WIRE CONNECTOR (9a) into

TOP CIRCUIT BOARD RECEPTOR (13) on Unit #2 . Fig.

15b.

9. Insert the other end of the EXTENSION WIRE (8) from Unit #3

into the SENSOR WIRE GROMMET (7) on the left side of Unit

#3. Insert EXTENSION WIRE CONNECTOR (9) into LOWER

CIRCUIT BOARD RECEPTOR (10) on Unit #3.

10. Repeat Steps 7 to 9 as necessary for additional Multi-AC

Units.

11. Once all wire connections are made. Install the COVER (2)

and COVER SCREWS (1) onto each ELECTRICAL BOX (3).

7 1

8

FROM UNIT #2

Fig. 15b

SENSOR WIREUnit #2

CONNECTOR

T O P

13

9a

10

9

2 3

 

7a

1

7

8

 

FROM UNIT #1

 

 

8

 

 

 

12

 

 

 

 

FROM

 

 

 

 

 

 

 

 

UNIT #3

BACK OF BOX (3)

REMOVE KNOCK-OUT (11),

 

 

 

11INSERT WIRE GROMMET (12)

 

 

 

M968550 REV. 1.5

9

Image 10
Contents Installation Instructions Concealed Flushometer For 1-1/2Top or Back Spud BowlsInstallation UnpackingFollowing items must be installed Roughing-in DimensionsPrior to Installation Recommended Tools FigInstall Sweat Solder Adapter Fig Install Electrical BOXAssembly Fig Flush OUT Supply Lines FigInstall Vacuum Breaker and Flush Connections Fig Consult Code for detailsInstall Flush Valve Fig Connect Flush Valve to Piping FigInstall the Sensor Wire Grommet 15 into Electrical BOX AC PowerConnect Front Panel to Connect Front Panel to Electrical BOX DC Power Battery Fig Install Front Panel FigConnect Override HOSES, AC & DC Power Fig Connect Solenoid Wiring and Power Supply FigUnit #3 Unit #1Unit #2 For AC-VERSIONRemove Front PANEL. For removing front panel Adjust Supply Stop FigSee for instructions Howto SET Detection Range If Required Stand outside of sensor detection aeraTroubleshooting Flow Charts Selectronic