American Standard 6067.22X, 6065.22X Install Flush Valve Fig, Connect Flush Valve to Piping Fig

Page 6

5INSTALL FLUSH VALVE; Fig. 8

1.Insert the side ADJUSTABLE TAILPIECE (1) on the FLUSH VALVE (2) into the SUPPLY STOP (3). Lubricate the TAILPIECE O-RING (4) with water if necessary. Lightly tighten COUPLING NUT (5). Fig. 8.

Important: Do not use lubricants (other than water) or any type of thread sealing paste or tape.

Fig. 8

 

3

 

 

1

5

4

2

 

6CONNECT FLUSH VALVE TO PIPING; Fig. 9

1.Align the FLUSH VALVE (2) (Fig. 9) directly above the VACUUM BREAKER TUBE (7) and VACUUM COUPLING NUT (6). Make sure that GASKET (10) is installed.

Note: There is a +13mm, -6mm (+1/2, -1/4) tolerance for the 121mm (4-3/4) dimension. Fig. 9.

2.Pull the VACUUM BREAKER TUBE (7) up to meet the threaded FLUSH VALVE CONNECTION (8) and hand tighten the COUPLING NUT (6). Align all components of the flush valve assembly. Fig. 9.

3.Lightly tighten the TAILPIECE COUPLING NUT (5) connection first, then the VACUUM BREAKER COUPLING NUT (6) and finally the SPUD COUPLING NUT (9). Once alligned correctly, use a wrench to tighten all couplings to make water tight connections.

Fig. 9.

4.Secure piping behind wall as required.

Fig. 9

121mm,+13mm, -6mm (4-3/4)(+1/2, -1/4)

2

5

8

10

 

6

 

7

9

5

M968550 REV. 1.5

 

Image 6
Contents Installation Instructions Concealed Flushometer For 1-1/2Top or Back Spud BowlsInstallation UnpackingFollowing items must be installed Roughing-in DimensionsPrior to Installation Recommended Tools FigInstall Sweat Solder Adapter Fig Install Electrical BOXAssembly Fig Flush OUT Supply Lines FigInstall Vacuum Breaker and Flush Connections Fig Consult Code for detailsInstall Flush Valve Fig Connect Flush Valve to Piping FigElectrical BOX AC Power Install the Sensor Wire Grommet 15 intoConnect Front Panel to Connect Front Panel to Electrical BOX DC Power Battery Fig Install Front Panel FigConnect Override HOSES, AC & DC Power Fig Connect Solenoid Wiring and Power Supply FigUnit #3 Unit #1Unit #2 For AC-VERSIONAdjust Supply Stop Fig Remove Front PANEL. For removing front panelSee for instructions Howto SET Detection Range If Required Stand outside of sensor detection aeraTroubleshooting Flow Charts Selectronic