15HOWTO SET DETECTION RANGE (If Required) ; Fig. 18 & 19

Note: The detection distance is preset and is ideal for most installations. Should an adjustment be required follow the steps below.

1.Remove FRONT PANEL (1). See Step 9 for removing front panel instructions.

2.Remove the four COVER SCREWS (2) and COVER

(3) from ELECTRICAL BOX (4). Fig. 18.

3.Disconnect GREY SENSOR WIRE (5) from CIRCUIT BOARD. (6).

4.Keeping hands away from the front of the sensor, reconnect the GREY SENSOR WIRE (5) and quickly hang the FRONT PANEL (1) onto the ELECTRICAL BOX (4). Do not secure the FRONT PANEL (1) at this time. Note:You have 5 seconds after connecting cable to begin program process.

5.While the SENSOR CONTROL LED (6) is blinking slowly, place your hand 1 to 2 in. (30-50mm.) in front of the sensor. Fig. 19.

6.When the LED (6) stops blinking and stays "ON", move your hand to the desired position from sensor (detection zone, 15-3/4" to 31-1/2", 400 to 800mm ) and hold in place until the LED (6) begins to blink again. Fig. 19a.

Note: Maximum Detection Zone is 15-3/4" to 31-1/2", (400 to 800mm ) from sensor.

7.Once the SENSOR CONTROL LED (6) begins to blink again, remove your hand from the detection zone. When the flashing stops, the detection distance is set.

8.Replace COVER (3). Tighten COVER SCREWS (2) firmly.

Fig. 18

 

5

 

T O P

2

6

 

4

 

3

1

5

9.Replace the FRONT PANEL (1). See Step 9 for instructions on installing front panel.

10.Actuate the FLUSH VALVE:

A)Cover sensor with hand for 10 seconds. NOTE:

Stand outside of sensor detection aera.

B)Remove hand from in front of the sensor, unit will

flush in approximately 3 seconds.

Fig. 19

Fig. 19a

 

 

6 BLINKING LED

BLINKING LED

 

 

MAXIMUM

 

1" - 2" (30mm - 50mm)

DETECTION ZONE

400mm TO 800mm

 

 

(15-3/4" TO 31-1/2")

11

M968550 REV. 1.5

 

Image 12
Contents Installation Instructions Concealed Flushometer For 1-1/2Top or Back Spud BowlsInstallation UnpackingRoughing-in Dimensions Prior to InstallationFollowing items must be installed Recommended Tools FigInstall Electrical BOX Assembly FigInstall Sweat Solder Adapter Fig Flush OUT Supply Lines FigInstall Vacuum Breaker and Flush Connections Fig Consult Code for detailsInstall Flush Valve Fig Connect Flush Valve to Piping FigElectrical BOX AC Power Install the Sensor Wire Grommet 15 intoConnect Front Panel to Connect Front Panel to Electrical BOX DC Power Battery Fig Install Front Panel FigConnect Override HOSES, AC & DC Power Fig Connect Solenoid Wiring and Power Supply FigUnit #1 Unit #2Unit #3 For AC-VERSIONAdjust Supply Stop Fig Remove Front PANEL. For removing front panelSee for instructions Howto SET Detection Range If Required Stand outside of sensor detection aeraTroubleshooting Flow Charts Selectronic