Q:How will I know if battery needs to be replaced?

A:Valve does not open and sensor blinks 2 times interrupted by pause for up to 7 days.

Q:Why has the flow rate of the faucet reduced significantly?

A:Check and clean aerator and strainer.

Q:There is no flow out of faucet when I'm in the sensor range?

A:Check sensor. If sensor blinks 2 times interrupted by pause, replace battery, or call 1800-442-1902.

Q:Why does the faucet operate the opposite of expected-Turns On when not in sensor range, but turns off when in sensor range?

A:Sensor wires to solenoid are reversed. Black to - & Red to + is correct.

Q:What is the normal operating pressure range?

A:Faucet will operate with supply pressures ranging from 20-80 psi.

8

M 9 6 5 2 7 1

 

Image 9 Contents
Installation Instructions GN Spout UnpackingRoughing-in Dimensions InstallationInstall Spout Assembly Fig Recommended ToolsMount Enclosure Fig Connect Spout Hose to Enclosure FigConnect Water Supply to Enclosure and Wall Supply Fig Electrical Connections Fig Electrical InstallationUnit #3 Unit #1 Unit #2For AC-VERSION Multi HOOK-UPMaintenance Test Installed FaucetHOW to Change Sensor Range Factory set at 6 Fig HOW to Clean Filter FigHOW to Clean and Remove the Flow Restrictor Fig General Cleaning FigFaqs