2MOUNT ENCLOSURE; Fig. 2
NOTE.The illustration shows the ICU FAUCET mounted on the American Standard ICU Sink. Faucet can be installed on almost any sink or countertop. For Faucet installation on the American Standard ICU Sink, see instruction sheet No.
1.For installation on ICU Sink mount ENCLOSURE (1) on MOUNTING BRACKET (2) with SCREWS (3).
2.For all other sinks or countertops determine location of ENCLOSURE (1). It must be located within the 14" (356mm) by 21" (533mm) shaded area shown in Figure 2 in order for electrical connections from the spout assembly to be completed.
NOTE: ENCLOSURE SUPPLY HOSE is 20". Distance between wall supply and ENCLOSURE (1) must be taken into consideration.
3.Remove 4 screws from COVER (6) and pull off COVER (6). Hold the ENCLOSURE (1) in desired location and mark the four mounting hole locations as shown. Fig. 2.
4.The ENCLOSURE (1) works best if secured to a wall stud or cross brace within the wall, using the SCREWS
(4) supplied. If the ENCLOSURE (1) is to be installed on a tile or plaster wall the ANCHORS (5) and SCREWS
(4) should be used. Fig. 2.
5.For installations on drywall or tiled walls; use ANCHORS (5) and SCREWS (4) for securing ENCLOSURE (1) to finished wall. Drill four 1/4" dia. holes a minimum of
3CONNECT SPOUT HOSE TO ENCLOSURE; Fig. 3
1.Connect SUPPLY NUT (1) from spout assembly to nipple on top of ENCLOSURE (2). Tighten with adjustable wrench to make a water tight connection. Fig. 3.
4CONNECT WATER SUPPLY TO ENCLOSURE AND WALL SUPPLY; Fig. 4
NOTE; If using the optional Mixing Valve See Sheet #M968808 for installation instructions.
1.Insert FIBER WASHER (4) into SUPPLY NUT (1) on ENCLOSURE (2).
2.Connect SUPPLY NUT (1) on ENCLOSURE (2) to FLEXIBLE SUPPLY HOSE (3).Tighten to make a water tight connection. Use two wrenches to tighten if necessary. Fig. 4.
3.Connect FLEXIBLE SUPPLY (3) directly to wall supply. Connection on FLEXIBLE SUPPLY (3) is 3/8" compression. Use adjustable wrench to tighten connection. Do not over tighten. Fig. 4a.
Note: FLEXIBLE SUPPLY (3) measures 20" from the bottom of the ENCLOSURE (1) base. If additional supply length is required, installer must purchase parts separately. Important: If FLEXIBLE SUPPLY (3) is too long, loop to avoid kinking.
Fig. 2 |
|
|
|
|
| 21" |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| (533mm) |
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 14" |
|
|
| ENCLOSURE |
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (356mm) |
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| MOUNTING |
|
|
|
| |||||||||
|
| 2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HOLES |
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
MOUNTING |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (71mm) |
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
BRACKET |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SUPPLIES | 3" |
|
|
|
|
| ||||||||||||||||||||||||||||||
|
| WASTE |
|
|
|
|
|
|
|
|
|
| (76mm) |
|
|
| (96mm) |
|
|
|
| |||||||||||||||
|
|
|
|
| 2MOUNTING |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
5 |
|
|
|
|
|
|
|
|
|
|
|
|
| BRACKET |
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
4 |
|
|
|
|
|
| 3 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||||
|
|
|
|
|
|
|
|
|
| 1 |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 6 |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| 20" |
|
|
|
|
|
|
| |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 1524mm | |||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (500mm) | ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| (60) |
1
NOTE: If using Mixing Valve (optional) See Sheet #M968808 for installation instructions.
Fig. 3 | 1 | |
| ||
| 2 |
|
|
|
Fig. 4
2 | 1 |
| DO NOT USE PIPE |
| |||
|
|
| SEALANT ON THREADS |
4
3
Fig. 4a
OTHER SINK
INSTALLATION
4" ELECTRICAL BOX OR EQUIVALENT BY OTHERS
COLD WATER OR 3
TEMPERED
WALL SUPPLY
M 9 6 5 2 7 1
3