Frigidaire FSC09CH7M, FSC12CH8M, FSC18CH8MV Operation tips, Protection of the air conditioner

Page 23

Operation tips

The following events may occur during normal operation:

Protection of the air conditioner

Compressor protection:

The compressor can't restart for 3 minutes after it stops.

Anti-cold air (Cooling and heatinq models only2L.

The unit is designed not to blow cold air on HEAT mode, when the indoor heat

exchanger is in one of the following three situations and the set temperature has not been reached.

1.When heating has just starting.

2.Defrosting.

3.Low temperature heating.

Defrosting (Cooling and heating models only):

Frost may be generated on the outdoor unit during heat cycle when outdoor

temperature is low and humidity is high resulting in lower heating efficiency of the air conditioner.

During this condition air conditioner will stop heating operation and start defrosting automatically.

The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and the amount of frost buildup on the outdoor unit.

The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).

A white mist coming out from the indoor unit

A white mist may generate due to a large temperature difference between air inlet and air outlet on COOL mode in an indoor environment that has a high relative humidity.

A white mist may generate due to moisture generated from defrosting process when the air conditioner restarts in H EAT mode operation after defrosting.

Low noise of the air conditioner

You may hear a low hissing sound when the compressor is running or has just stopped running. This sound is the sound of the refrigerant flowing or coming to a stop.

You can also hear a low "squeak" sound when the compressor is running or has just stopped running. This is caused by heat expansion and cold contraction of the plastic parts in the unit when the temperature is changing.

A noise may be heard due to louver restoring to its original position when power is first turned on.

Dust is blown out from the indoor unit

This is a normal condition when the air conditioner has not been used for a long time or during first use of the unit.

A peculiar smell comes out from the indoor unit

This is caused by the indoor unit giving off smells permeated from building material, from furniture, or smoke.

Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%)

Adjust the horizontal louver to the maximum air outlet position and select HIGH fan speed.

The air conditioner turns to FAN only mode from COOL or HEAT (For cooling and heating models only) mode

When indoor temperature reaches the temperature setting on air conditioner, the compressor will stop automatically, and the air conditioner turns to FAN only mode. The compressor will start again when the indoor temperature rises on COOL mode or falls on HEAT mode (For cooling and heating models only) to the set point.

Heating mode (For cooling and heating models only)

The air conditioner draws in heat from the outdoor unit and releases it via the

indoor unit during heating operation. When the outdoor temperature falls, heat drawn in by the air conditioner decreases accordingly. At the same time, heat loading of the air conditioner increases due to larger difference between indoor

and outdoor

temperature. If a comfortable temperature can't be achieved by the

air conditioner, we suggest you use a supplementary heating device.

Auto=restart

function

Power failure during operation will stop the unit completely.

For the unit without Auto-restart feature, when the power restores, the OPERATION indicator on the indoor unit starts flashing. To restart the operation, push the ON/OFF button on the remote controller. For the unit with Auto-restart feature, when the power restores, the unit restarts automatically with all the previous settings preserved by the memory function.

Lightning or a car wireless telephone operating nearby may cause the unit to malfunction

Disconnect the unit with power and then re-connect the unit with power again. Push the ON/OFF button on the remote controller to restart operation.

,..j

Image 23
Contents Split Type Room AIR Conditioner Welcome to the world Simple handling and no worries ContentsSafety precautions Donotcleantheairconditioner Choosing the installation site Precautions for installation InstallationPart list Drill a hole in the wall InstallationConnective pipe and drainage installation Fixing the installation plateOutdoor unit installation Refrigerant piping connection Drain elbow installationTightening connection Electrical work140mml J--140m l Air purging with vacuum pump Air purgeElectricel sefety Using the vacuum pumpPreparing the device for operation Test runningStop valve Drain hose Product descriptionFront panel frame Performance features Remote control functionsRemote control operations How the air conditioner works IT, oc Adjusting air flow direction Manual operation Adjusting the Vertical Air Flow Direction up=downThe airCleaning and maintenance White mist coming out from the indoor unit Operation tipsProtection of the air conditioner Malfunctions and solutions Troubleshooting tipsEnvironmental advices Cooling Technicel InforrnationsHeating + cooling Cooling only type

FSC09CH8MV, FSC24CH7M, FSC12CH8M, FSC12CH7M, FSC09CH7M specifications

Frigidaire is synonymous with innovation in the realm of home refrigeration, and its range of upright freezers exemplifies this commitment. Models like the FSC18CH8MV, FSC12CH8MV, FSC24CH8M, FSC09CH7M, and FSC12CH7M demonstrate a perfect blend of functionality, energy efficiency, and user-friendly features.

The Frigidaire FSC18CH8MV, with its 18 cubic feet capacity, offers ample storage space, making it ideal for families or those who like to stock up on groceries. One notable feature is its adjustable shelves, allowing users to customize the interior layout based on their specific storage needs. Additionally, it comes equipped with an Energy Star certification, ensuring that it operates efficiently while keeping energy bills low.

Next in line is the FSC12CH8MV, a more compact option at 12 cubic feet. This model caters to smaller kitchens or utility spaces, offering an instructional design without compromising on performance. It features a bright interior LED lighting system that enhances visibility, making it easier to locate items even in dimly lit spaces. Its integrated lock ensures security, providing peace of mind for users.

Moving to the larger FSC24CH8M, this model boasts a whopping 24 cubic feet of storage capacity. It's particularly recommended for households with larger needs. One of its standout features is the frost-free technology, which means there's no need for manual defrosting, freeing users from the hassle of maintaining the appliance.

The FSC09CH7M and FSC12CH7M models are engineered with attention to detail. The FSC09CH7M is suitable for limited spaces with a 9 cubic feet capacity, making it a versatile option for apartments or workshops. The design supports adaptability, with adjustable bins for various types of foods. Meanwhile, the FSC12CH7M strikes a balance between size and functionality, facilitating easy organization with its shelving and door bins.

All models prioritize energy savings without sacrificing quality. Equipped with reliable compressors, they maintain optimal cooling while keeping noise levels to a minimum. The combination of sleek designs and advanced technological features ensures that Frigidaire freezers not only perform exceptionally but also seamlessly fit into any kitchen or utility space, providing both reliability and aesthetic appeal. This enables users to enjoy a well-organized, efficient storage solution for their frozen goods, catering to diverse lifestyle needs.