• OPERATING INSTRUCTIONS •
WHEN THE AIR CONDITIONER IS NOT GOING TO BE USED FOR A LONG TIME
1 Set to the highest temperature in manual COOL mode, and operate for 3 to 4 hours. Page 4
This dries the inside of the unit.
2 | Press |
| to stop the operation. |
| |||
| |||
|
|
| |
3 | Turn off the breaker and/or disconnect the power sup- | ||
| ply plug. |
|
|
|
|
| |
4 | Remove all batteries from the remote controller. |
When using the air conditioner again:
1 |
| ||
Clean the air filter. | Page 7 |
| |
|
| ||
2 | Check that the air inlet and outlet of the indoor and | ||
| outdoor units are not blocked. | ||
|
| ||
3 | Check that the earth is connected correctly. |
INSTALLATION PLACE AND ELECTRICAL WORK
Installation place
Avoid installing the air conditioner in the following places.
•Where there is much machine oil.
•Salty places such as the seaside.
•Where sulfide gas is generated such as a hot spring.
•Where oil is splashed or where the area is filled with oily smoke.
•Where there is
•Where the air from the outdoor unit air outlet is blocked.
•Where the operation sound or air from the outdoor unit does not bother the house next door.
|
|
|
|
| The installation location of the outdoor unit should | |||
|
|
|
|
| be at least 3 m away from the antennas for TV sets, | |||
|
|
|
|
| radios, etc. In areas where the reception is weak, | |||
|
|
|
|
| provide greater space between the outdoor unit and | |||
|
|
|
|
| the antenna of the affected device if operation of the air | |||
|
|
|
|
| conditioner interferes with radio or TV reception. | |||
|
|
|
|
|
|
| ||
To prevent the effects | fluorescent lamp |
|
|
|
|
| ||
|
|
|
|
|
|
| ||
of a fluorescent lamp, |
|
|
|
|
|
| wall, etc. | |
keep as far apart as |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
possible. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Well- |
| |
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| ventilated dry |
|
|
|
|
|
|
|
| ||
|
|
| Keep a space to |
|
| place |
| |
|
|
|
|
|
|
| ||
|
|
| prevent the pic- |
|
|
|
| |
|
|
|
|
|
|
| ||
|
|
| ture distortion or |
| 100 mm or |
|
| |
|
|
| the noise. |
|
|
|
| |
1 m |
|
|
|
| more | (SFD18/SD24) | ||
|
|
|
|
| ||||
|
|
|
|
|
| 200/500 mm | ||
or more |
|
| TV |
|
|
| ||
| 1 m |
|
|
|
| or more | ||
Cordless | or more |
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
phone or |
|
|
|
|
|
|
|
|
Portable |
|
|
| 3 m or |
|
| ||
phone |
|
|
|
|
| |||
Radio |
|
| more |
|
| |||
|
|
|
|
|
Electrical work
•Provide an exclusive circuit for the power supply of the air conditioner.
•Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
SPECIFICATIONS
Model |
| |||
|
|
|
| |
Dimensions | Indoor | 325 × 1100 × 258 | 325 × 1100 × 258 | |
H × W × D (mm) | Outdoor | 550 × 800 × 285 | 850 × 840 × 330 | |
Weight (kg) | Indoor | 16 | 16 | |
Outdoor | 34 | 65 | ||
| ||||
|
|
|
| |
EER |
| 3.23 | 3.23 | |
|
|
|
|
Note:
1.Rating condition
Cooling — Indoor: 27°C DB, 19°C WB Outdoor: 35°C DB, 24°C WB
2.Guaranteed operating range
| Indoor | Outdoor |
|
Upper limit | 32°C DB | 43°C DB |
|
23°C WB | — |
| |
|
| ||
Lower limit | 21°C DB | 21°C DB |
|
15°C WB | — |
| |
|
| ||
|
|
|
|
Environment care
Mitsubishi Electric Air conditioner has been designed
Turn off air conditioner in case of not in use.
Turn off ventilator in case of not in use.
The set temperature should not be set lower than 25°C.
The cleaning of condensing coil should be performed at least every 3 months.
The cleaning of air cleaning filter should be performed in the period described in this manual.