Mitsubishi Electronics TC-24A installation manual Safety Precautions, General precautions

Page 2

Safety Precautions

Thoroughly read the following safety precautions prior to installation. Observe the following precautions to ensure safety.

WARNING

Indicates a risk of death or serious injury.

CAUTION

Indicates a risk of serious injury or structural damage.

Nomenclature

 

 

 

 

(Prohibited actions)

(Do not touch)

(No water)

(No wet hands) (Electric shock hazards) (Injury hazards) (Important actions)

After reading this manual, pass it on to the end user to retain for future reference.

Keep this manual for future reference and refer to it as necessary. This manual should be made available to those who repair or relocate the controller. Make sure that the manual is passed on to any future TC-24A users.

All electric work must be performed by qualified personnel.

General precautions

WARNING

Do not install the unit in a place where large amounts of oil, steam, organic solvents, or corrosive gases, such as sulfuric gas, are present or where acidic/alkaline solutions or sprays are used frequently. These substances can compromise the performance of the unit or cause certain components of the unit to corrode, which can result in electric shock, malfunc- tions, smoke, or fire.

To reduce the risk of shorting, current leakage, electric shock, malfunctions, smoke, or fire, do not wash the controller with water or any other liquid.

To reduce the risk of electric shock, malfunctions, smoke or fire, do not operate the switches/buttons or touch other electrical parts with wet hands.

To reduce the risk of injury or electric shock, before spraying a chemical around the controller, stop the operation and cover the controller.

To reduce the risk of injury or electric shock, stop the operation and switch off the power supply before cleaning, maintaining, or inspecting the controller.

Properly install all required covers to keep moisture and dust out of the controller. Dust accumulation and water can cause electric shock, smoke, or fire.

CAUTION

To reduce the risk of fire or explosion, do not place flammable materials or use flammable sprays around the controller.

To reduce the risk of damage to the controller, do not directly spray insecticide or other flammable sprays on the controller.

To reduce the risk of electric shock or malfunctions, do not touch the touch panel, switches, or buttons with a pointy or sharp object.

To reduce the risk of injury and electric shock, avoid contact with sharp edges of certain parts.

To avoid injury from broken glass, do not apply excessive force on the glass parts.

To reduce the risk of injury, wear protective gear when working on the controller.

Precautions during installation

WARNING

Do not install the controller where there is a risk of leaking flammable gas.

If flammable gas accumulates around the controller, it may ignite and cause a fire or explosion.

Properly dispose of the packing materials. Plastic bags pose suffocation hazard to children.



Image 2
Contents TC-24A Safety Precautions General precautionsPrecautions for moving or repairing the controller Function List Function DescriptionScreen Function List contd Screen Names and Functions of Controller Components Touch panel / Buttons How to move to the Maintenance screen How to switch the Home screenHow to move to the Main Menu screen Zoom-out screen To the Grid Zoom-in screenList screen To the Group To the LISTscreen screenOperation mode Buttons Home screen①GRID screen button ⑬Set temperature button⑰Set temperature button Setback mode ⑪Group buttonIcon Displays Home screen Interlocked ventilation Lossnay General equipment iconError Filter sign Group No Mode ErrorSet temperature Fan speed LouverLossnay group Fan speed displayGeneral equipment icon General equipment groupGrid zoom-out screen Grid zoom-in screen List screen Basic OperationsScreen selection During receiving the external input signal Group selectionOperating the Air conditioning unit group Basic Operations contdON/OFF operation Basic operations Group screenSetback mode TouchWhile the setback operation is performed Air direction useable only while the unit is in operation After setting a through D , touch the OK buttonFan speed useable only while the unit is in operation Louver useable only while the unit is in operationMode Hold Function SettingFan speed setting Operating the General equipment groupMultiple group selection screen Lock ButtonsMenu Screen Button Settings ① Home buttonTime and Schedule Time and Schedule screen Usage Main Menu SettingsSetting the date, time, and display format Main Menu Time and ScheduleSet Schedule screens Setting the operation scheduleSchedule setting flowchart Schedule Setting Procedures Time and Schedule screen contdButton to access the Edit Pattern screen Copying, pasting, deleting, and inserting settings Copying and pasting the existing settings Deleting selected settingsInserting an event Icon DefinitionsChecking the Weekly/One Day Schedule Settings Main Menu Time and Schedule Check Current SettingsSave Restrictions Settings① Enable/Disable Lock button To temporarily unlock all items To logTo lock or unlock buttons Lockable functions and the corresponding buttonsGroup Restrictions Settings contdEdit Page Select All button ① Show Group Name List buttonLocked → Unlocked To select the display language To select the temperature unitControl Panel To show or hide the room temperature To set the backlight timeout timeControl Panel contd To change the group nameCharacter input screen To enter a character stringController button settings To select the groups on which to execute SET Back functionShow Group Name List button Operation mode 2 defaultTo select the groups on which to execute the Hold function To adjust the brightness Adjusting the volume and brightnessTo adjust the volume Calibrating the touch panel Main Menu Control Panel Touch Panel CalibrationTo reset the error Checking or resetting the Error or Filter SignTo check the error System ManagementTo reset the Filter Sign after cleaning the filter Using the System-Changeover function System Management contdOperation mode To clean the touch panel MaintenanceTouch Panel Cleaning screen Troubleshooting SolutionWT05827X01

TC-24A specifications

The Mitsubishi Electronics TC-24A is a cutting-edge air conditioning unit designed to provide comfort and efficiency in various environments. Known for its sleek design and advanced technology, the TC-24A is well-suited for both residential and commercial applications. It stands out in the HVAC market due to its innovative features that prioritize energy efficiency and user convenience.

One of the main features of the Mitsubishi TC-24A is its inverter technology. This system allows the compressor to operate at variable speeds, providing precise temperature control while minimizing energy consumption. By adjusting its output based on the desired cooling or heating requirements, the unit can operate more efficiently than traditional fixed-speed air conditioners, resulting in significant savings on energy bills.

The TC-24A also incorporates advanced filtration systems. These filters are designed to capture dust, allergens, and other particulates, ensuring that the air circulated within the space is clean and healthy. With features like a washable pre-filter and options for advanced filtration, users can enjoy improved indoor air quality, making it an excellent choice for allergy sufferers or those with respiratory sensitivities.

Additionally, the TC-24A is equipped with a user-friendly remote control. This allows users to adjust settings from a distance, including temperature, fan speed, and operating modes. The unit also features programmable timers and settings, enabling users to customize their comfort levels according to their daily schedules.

Another remarkable aspect of the TC-24A is its quiet operation. Designed with noise-reduction technology, the air conditioner operates at lower sound levels, providing a peaceful environment – an essential feature for bedrooms, offices, and other quiet spaces.

In terms of design, the TC-24A boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size and versatility make it suitable for installation in different settings, maximizing space efficiency.

Overall, the Mitsubishi Electronics TC-24A is not just an air conditioning unit but a comprehensive solution for climate control, combining energy efficiency, advanced features, and user-centered design. Whether for home or business use, it promises to deliver reliable performance, ensuring comfort throughout the year.