Mitsubishi Electronics TC-24A installation manual While the setback operation is performed

Page 22

Basic Operations (cont'd)

While the setback operation is performed

To change the setback maximum/minimum limit temperature

Touch the set temperature button to display the screen for setback maximum/minimum limit temperature.

2

Then, one of the screens on the right appear.

 

 

 

 

 

 

 

 

 

 

 

 

Touch the OVERRIDE button (2) to switch

 

 

 

 

 

 

 

 

 

 

 

 

between [TEMPORARY] and [PERMANENT]

 

 

 

 

 

 

(shown above the OVERRIDE button).

 

 

 

 

 

 

 

 

 

 

 

 

 

Touch (3) to set the maximum/minimum limit.

 

 

 

 

 

When [TEMPORARY] is selected, the timer will appear, and the

 

 

 

 

 

original maximum/minimum limit temperature will appear above

 

 

 

 

 

the timer.

 

 

 

 

 

Touch (4) to set the timer.

3

 

Then, touch the [OK] button (5).

 

5

When the scheduled setback operation is performed,

 

 

 

 

 

[TEMPORARY] will appear on the screen.

 

 

 

 

 

When the setback operation is performed by selecting the setback

 

 

 

 

 

mode or pressing the SET BACK button, [PERMANENT] will

 

 

 

 

 

appear on the screen.

3

 

*After the set time has elapsed, the setback control resumes to the original maximum/minimum limit temperature.

*When the set temperature is changed through other controllers while setback operation (override) is executed, the temperature display is changed and setback operation (override) is suspended. After two hours have elapsed, the setback operation resumes to the original maximum/minimum limit temperature.

*The maximum/minimum limit temperature cannot be temporarily changed on the multiple group selection screen. (Override cannot be used.)

*The override time can be set up to four hours in 10-minute increments.

2

1

2

4

1

2

Timer does not appear on the screen.

22

Image 22
Contents TC-24A Safety Precautions General precautionsPrecautions for moving or repairing the controller Function List Function DescriptionScreen Function List contd Screen Names and Functions of Controller Components Touch panel / Buttons How to move to the Maintenance screen How to switch the Home screenHow to move to the Main Menu screen Zoom-out screen To the Grid Zoom-in screenList screen To the Group To the LISTscreen screenOperation mode Buttons Home screen①GRID screen button ⑬Set temperature button⑰Set temperature button Setback mode ⑪Group buttonIcon Displays Home screen Interlocked ventilation Lossnay General equipment iconError Filter sign Group No Mode ErrorSet temperature Fan speed LouverLossnay group Fan speed displayGeneral equipment icon General equipment groupScreen selection Basic OperationsGrid zoom-out screen Grid zoom-in screen List screen During receiving the external input signal Group selectionOperating the Air conditioning unit group Basic Operations contdON/OFF operation Basic operations Group screenSetback mode TouchWhile the setback operation is performed Air direction useable only while the unit is in operation After setting a through D , touch the OK buttonFan speed useable only while the unit is in operation Louver useable only while the unit is in operationMode Hold Function SettingFan speed setting Operating the General equipment groupMultiple group selection screen Lock ButtonsMenu Screen Button Settings ① Home buttonTime and Schedule Time and Schedule screen Usage Main Menu SettingsSetting the date, time, and display format Main Menu Time and ScheduleSchedule setting flowchart Setting the operation scheduleSet Schedule screens Schedule Setting Procedures Time and Schedule screen contdButton to access the Edit Pattern screen Copying, pasting, deleting, and inserting settings Copying and pasting the existing settings Deleting selected settingsInserting an event Icon DefinitionsChecking the Weekly/One Day Schedule Settings Main Menu Time and Schedule Check Current Settings① Enable/Disable Lock button Restrictions SettingsSave To temporarily unlock all items To logTo lock or unlock buttons Lockable functions and the corresponding buttonsEdit Restrictions Settings contdGroup Page Select All button ① Show Group Name List buttonLocked → Unlocked Control Panel To select the temperature unitTo select the display language To show or hide the room temperature To set the backlight timeout timeControl Panel contd To change the group nameCharacter input screen To enter a character stringController button settings To select the groups on which to execute SET Back functionTo select the groups on which to execute the Hold function Operation mode 2 defaultShow Group Name List button To adjust the volume Adjusting the volume and brightnessTo adjust the brightness Calibrating the touch panel Main Menu Control Panel Touch Panel CalibrationTo reset the error Checking or resetting the Error or Filter SignTo check the error System ManagementTo reset the Filter Sign after cleaning the filter Using the System-Changeover function System Management contdOperation mode Touch Panel Cleaning screen MaintenanceTo clean the touch panel Troubleshooting SolutionWT05827X01

TC-24A specifications

The Mitsubishi Electronics TC-24A is a cutting-edge air conditioning unit designed to provide comfort and efficiency in various environments. Known for its sleek design and advanced technology, the TC-24A is well-suited for both residential and commercial applications. It stands out in the HVAC market due to its innovative features that prioritize energy efficiency and user convenience.

One of the main features of the Mitsubishi TC-24A is its inverter technology. This system allows the compressor to operate at variable speeds, providing precise temperature control while minimizing energy consumption. By adjusting its output based on the desired cooling or heating requirements, the unit can operate more efficiently than traditional fixed-speed air conditioners, resulting in significant savings on energy bills.

The TC-24A also incorporates advanced filtration systems. These filters are designed to capture dust, allergens, and other particulates, ensuring that the air circulated within the space is clean and healthy. With features like a washable pre-filter and options for advanced filtration, users can enjoy improved indoor air quality, making it an excellent choice for allergy sufferers or those with respiratory sensitivities.

Additionally, the TC-24A is equipped with a user-friendly remote control. This allows users to adjust settings from a distance, including temperature, fan speed, and operating modes. The unit also features programmable timers and settings, enabling users to customize their comfort levels according to their daily schedules.

Another remarkable aspect of the TC-24A is its quiet operation. Designed with noise-reduction technology, the air conditioner operates at lower sound levels, providing a peaceful environment – an essential feature for bedrooms, offices, and other quiet spaces.

In terms of design, the TC-24A boasts a modern aesthetic that can seamlessly blend into various interior styles. Its compact size and versatility make it suitable for installation in different settings, maximizing space efficiency.

Overall, the Mitsubishi Electronics TC-24A is not just an air conditioning unit but a comprehensive solution for climate control, combining energy efficiency, advanced features, and user-centered design. Whether for home or business use, it promises to deliver reliable performance, ensuring comfort throughout the year.