ELECTRICAL PARTS PCA-A24GA1PCA-A30GA1PCA-A36GA1PCA-A42GA1

1

6

2

3

4

5

TEMP.ON/OFF

8

7

 

RoHS

 

 

 

 

 

Q'ty/ set

 

Wiring

Recom-

No.

Parts No.

Parts Name

Specifications

PCA-A

Remarks

24/30

36/42

(Drawing No.)

Diagram

mended

 

 

 

 

 

 

Symbol

Q'ty

 

 

 

 

 

 

 

GA1

 

 

 

1

G

T7W

E18

255

CAPACITOR

4= 440V

1

 

 

C

 

G

T7W

E19

255

CAPACITOR

5= 440V

 

1

 

C

 

 

 

 

 

2

G

T7W

E56

310

INDOOR CONTROLLER BOARD

 

1

1

 

I.B

 

3

G

T7W

E41

716

TERMINAL BLOCK

3P(L1,L2,GR)

1

1

 

TB2

 

4

G

R01

E18

246

TERMINAL BLOCK

3P(S1,S2,S3)

1

1

 

TB4

 

5

G

R01

E21

246

TERMINAL BLOCK

2P(1,2)

1

1

 

TB5

 

6

G

T7W

E35

313

POWER BOARD

 

1

1

 

P.B

 

7

G

T7W

A01

305

REMOTE CONTROLLER CORD

 

1

1

 

 

 

8

G

T7W

E14

713

REMOTE CONTROLLER

PAR-21MAA

1

1

 

R.B

 

HEAD OFFICE : TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

CCopyright 2006 MITSUBISHI ELECTRIC ENGINEERING CO., LTD.

 

Distributed in Jun. 2007

No.OC368 REVISED EDITION-B PDF 9

 

Distributed in Aug. 2006

No.OC368 REVISED EDITION-A PDF 9

New publication, effective Jun. 2007

Distributed in Feb. 2006

No.OC368 PDF 10

Specifications subject to change without notice.

Made in Japan

 

 

Image 36
Contents Contents Revised EDITION-BPCA-A24GA PCA-A30GATechnical Data Book Technical ChangesReference Manual Safety Precaution Always Observe for SafetyWhen charging directly from cylinder Additional refrigerant chargePart Names and Functions Indoor UnitDisplay Section Operation Mode display Mode Select buttonTemperature setting display Timer displaySpecifications Service RefPCA-A30GA, PCA-A30GA1Single phase, 60Hz, 208/230V PCA-A36GA, PCA-A36GA1Single phase, 60Hz, 208/230VNoise Criterion Curves PCA-A24GA1PCA-A30GA1 PCA-A36GA1Outlines and Dimensions PCA-A24GA PCA-A24GA1 PCA-A30GA PCA-A30GA1PCA-A36GA PCA-A42GA PCA-A36GA1 PCA-A42GA1 Unit inchmmWiring Diagram Indoor unit Installation ManualRefrigerant System Diagram Heat exchangerTroubleshooting TroubleshootingSELF-DIAGNOSIS Action Table Pipe temperature Cause Countermeasure Freezing/overheating protection isWorking Cause Countermeasure Pipe temperature thermistor Remote controller transmissionErrorE0/signal receiving errorE4 ErrorE3/signal receiving errorE5Error Signal receiving error Error Transmitting errorRemote controller control board Indoor controller boardTroubleshooting by Inferior Phenomena Phenomena Cause CountermeasureIs off Ply system4Receiver for wireless remote Is blinking3Upward/downward vane Performance failurePage Vane motor MV Test Point Diagram Between 1 to 3 12.6-13.7V DC Pin1 +Connect to the indoor controller board CN2D PCA-A36GA PCA-A36GA1 Functions of DIP Switch and Jumper Wire ModelsDisassembly Procedure Operating Procedure Photos & IllustrationsRemoving the air intake grille Removing the electrical boxOperating Procedure Removing the fan motor MFRemoving the sirocco fan Remove the air intake grilleOperating Procedure Photos Removing the vane motor MVRemoving the Indoor coil thermistor TH2/TH5 Removing the Under panelRemoving the drain pan Removing the guide vaneRemove the intake grille. See the figure Removing the Auto vaneRemoving the heat exchanger Parts No Parts Name Specifications Drawing NoR01 29J 130 R01 35J 130Structural Part PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA Electrical Parts PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA Parts Name Specifications RoHSRemarks Parts NoStructural Part PCA-A24GA1PCA-A30GA1PCA-A36GA1PCA-A42GA1 Wiring Recom Electrical Parts PCA-A24GA1PCA-A30GA1PCA-A36GA1PCA-A42GA1RoHS Qty/ set