Mitsubishi Electronics PCA-A24GA service manual Part Names and Functions, Indoor Unit

Page 5

4

PART NAMES AND FUNCTIONS

Indoor Unit

Left/right guide vanes

Air outlet

Change the direction of airflow from the horizontal blower.

Long-life filter

Removes dust and foreign matter from air coming in through the grille (Recommended cleaning interval : Approx. every 2,500 operating hours)

Up/down guide vanes

Change the direction of airflow from the vertical blower.

Intake grille

Air intake

Wired remote controller

Once the controllers are set, the same operation mode can be repeated by simply pressing the ON/OFF button.

Temperature setting buttons

 

 

 

Down

 

 

 

Up

 

 

 

Timer Menu button

 

 

 

(Monitor/Set button)

 

 

 

Mode button (Return button)

 

 

 

 

 

TEMP.

 

Set Time buttons

 

 

 

Back

 

MENU

ON/OFF

Ahead

BACK

MONITOR/SET

DAY

 

Timer On/Off button

PAR-21MAA

CLOCK

(Set Day button)

 

 

 

Opening the

 

 

 

lid

 

 

 

 

ON/OFF

 

 

FILTER

 

CHECK

TEST

OPERATION

CLEAR

 

ON/OFF button

Fan Speed button

Filter button (<Enter> button)

Test Run button

Check button (Clear button)

Airflow Up/Down button

Louver button

( Operation button)

To return operation number

Ventilation button

( Operation button)

Built-in temperature sensor

To go to next operation number

5

Image 5
Contents Revised EDITION-B ContentsPCA-A24GA PCA-A30GA Reference Manual Technical Data Book Technical Changes Always Observe for Safety Safety PrecautionAdditional refrigerant charge When charging directly from cylinderIndoor Unit Part Names and FunctionsDisplay Section Mode Select button Operation Mode displayTemperature setting display Timer displayService Ref SpecificationsPCA-A30GA, PCA-A30GA1Single phase, 60Hz, 208/230V PCA-A36GA, PCA-A36GA1Single phase, 60Hz, 208/230VPCA-A24GA1 Noise Criterion CurvesPCA-A30GA1 PCA-A36GA1PCA-A24GA PCA-A24GA1 PCA-A30GA PCA-A30GA1 Outlines and DimensionsUnit inchmm PCA-A36GA PCA-A42GA PCA-A36GA1 PCA-A42GA1Indoor unit Installation Manual Wiring DiagramHeat exchanger Refrigerant System DiagramTroubleshooting TroubleshootingSELF-DIAGNOSIS Action Table Working Pipe temperatureCause Countermeasure Freezing/overheating protection is Remote controller transmission Cause Countermeasure Pipe temperature thermistorErrorE0/signal receiving errorE4 ErrorE3/signal receiving errorE5Error Transmitting error Error Signal receiving errorRemote controller control board Indoor controller boardPhenomena Cause Countermeasure Troubleshooting by Inferior PhenomenaIs off Ply systemIs blinking 4Receiver for wireless remote3Upward/downward vane Performance failurePage Vane motor MV Connect to the indoor controller board CN2D Test Point DiagramBetween 1 to 3 12.6-13.7V DC Pin1 + PCA-A36GA PCA-A36GA1 Models Functions of DIP Switch and Jumper WireOperating Procedure Photos & Illustrations Disassembly ProcedureRemoving the air intake grille Removing the electrical boxRemoving the fan motor MF Operating ProcedureRemoving the sirocco fan Remove the air intake grilleRemoving the vane motor MV Operating Procedure PhotosRemoving the Indoor coil thermistor TH2/TH5 Removing the Under panelRemoving the guide vane Removing the drain panRemove the intake grille. See the figure Removing the Auto vaneRemoving the heat exchanger Drawing No Parts No Parts Name SpecificationsR01 29J 130 R01 35J 130Structural Part PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA Electrical Parts PCA-A24GA PCA-A30GA PCA-A36GA PCA-A42GA RoHS Parts Name SpecificationsRemarks Parts NoStructural Part PCA-A24GA1PCA-A30GA1PCA-A36GA1PCA-A42GA1 RoHS Qty/ set Wiring RecomElectrical Parts PCA-A24GA1PCA-A30GA1PCA-A36GA1PCA-A42GA1