Mitsubishi Electronics 20-L, 20 PRH-5, 8, 10, 15 manual Safety for USE, For correct installation

Page 3

SAFETY FOR USE

Before conducting installation work, please read this ''SAFETY FOR USE'' carefully

for correct installation.

Since the caution items shown here contain important description relative to safety, please observe them without fail.

Warning

Erroneous handling gives a high possibility to induce serious results such as

death or heavy injury.

 

 

Caution

Erroneous handling may induce serious injury depending on the situation.

 

 

After reading, please keep it with you together the Instruction Manual, and read it again at the movement of the unit.

Warning

The unit should not be installed by the user.

If the unit is installed improperly, explosion, water leakage, electric shock or fire may be result. Consult your dealer or specialist subcontractor for repair and movement.

For installation, conduct the work correctly by following the Installation Manual.

Improper installation may cause a fire, electrical shock or water leakage.

Install the unit on a spot sufficiently durable against the unit weight.

Insufficient durability can cause an injury by the falling down of unit.

All electric work must be performed by licensed technician, according to local regulations and the instructions given in this manual.

The units should be powered by dedicated power lines. Power lines with insufficient capacity or improper electrical work may result in electric shock or fire.

Use only the specified cables for wiring.

The connections must be made secured without tension the terminals.

Improper connection or fastening can cause a fire or electrical shock.

The unit should be installed according to the instructions in order to minimize the risk of damage from earthquakes, typhoons or strong winds. Improper installation work can cause an injury by the falling down of the unit.

The unit must be installed on stable, flat surface, in a place where there is no accumulation of snow, leaves or rubbish.

The unit should be installed in a location where air and noise emitted by the unit will not disturb the neighbors.

If the unit is loosely mounted, it may fall, and cause injury.

Never repair the unit, remodel or transfer it to another site by yourself.

If they are performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer.

Use only the specified refrigerant (R-22) to charge the refrigerant circuit.

Do not mix it with any other refrigerant and do not allow air to remain in the circuit.

Air enclosed in the circuit can cause high pressure resulting in a rupture and other hazards.

After completing installation work, make sure that refrigerant gas has not leaked.

If refrigerant gas has leaked and exposed to fan heater, stove, oven and so on, it may generate noxious gases.

Take a proper measure to suppress the critical concentration of refrigerant if leaked when installing the unit in a small room.

The limit density is made not to be exceeded even if the refrigerant leaks by any chance.

You are necessary to ventilation measures to prevent the accident. If the refrigerant leaks, hypoxia accident may caused.

For the countermeasure to be taken, consult your dealer.

The terminal block cover of unit must be firmly attached to prevent entry of dust and moisture. Improper mounting of the cover cause electric shock or fire.

Use only optional parts authorised by Mitsubishi Electric.

If the accessories are installed improperly, water leakage, electric shock or fire may result.

Ask your dealer or an authorised company to install them.

- 2 -

Image 3
Contents Heat Pump Data BookContents For correct installation Safety for USEDo not wash the unit with water Complete Line UP High Sensible Cooling Capacity FeaturesDescriptions Mechanical SpecificationsPRH PRH-L Typical Installation ExampleGross SpecificationsElectrical Data CoolingHeating PR-5YC PRH-5YA-L Capacity TablesCooling Capacity Nominal Air FlowPR-5YC,PRH-5YA,PRH-5YA-L Factor for Various Air FlowRange PRH-5YA Heating Capacity Nominal Air FlowPRH-5YA,PRH-5YA-LPR-8YC PRH-8YA-L PRH-8YA Cooling Capacity Nominal Air FlowPR-8YC,PRH-8YA,PRH-8YA-LHeating Capacity Nominal Air FlowPRH-8YA,PRH-8YA-L PR-8YC PRH-8YA-LPRH-8YA PR-10YC PRH-10YA-L PRH-10YA Cooling Capacity Nominal Air FlowPR-10YC,PRH-10YA,PRH-10YA-LHeating Capacity PRH-10YA-LPRH-10YA PR-15YC PRH-15YA-L PRH-15YA Cooling Capacity Nominal Air FlowPR-15YC,PRH-15YA,PRH-15YA-LPRH-15YA PR-15YC PRH-15YA-LPR-20YC PRH-20YA-L PRH-20YA Cooling Capacity Nominal Air FlowPR-20YC,PRH-20YA,PRH-20YA-LPRH-20YA PRH-20YA-LPRH-YA-L Operation rangePR-YC PRH-YARpm FAN PerformanceOperation range Fan speed Pressure Pulley outside dimensions are shown below Unit mm PR-5YC PRH-5YA PRH-5YA-L PR-8YC PRH-8YA PRH-8YA-L NC CurvesPR-15YC PR-10YCPR-20YC Outline DimensionsPR-15,20YC PRH-15, 20YA PRH-15, 20YA-L PR-8,10YC PRH-8, 10YA PRH-8, 10YA-LPR-5, 8, 10YC Standard Wiring DiagramsPR-15, 20YC Standard Special Order K Control PR-5, 8, 10YCInternal Protector Special Order LOW TemperaturePR-15, 20YC 50Hertz Special Order K Control & LOW TemperaturePRH-5, 8, 10YA-L Standard PRH-5, 8, 10YAPRH-15, 20YA-L Standard PRH-5, 8, 10YA PRH-5, 8, 10YA-L 10YA PRH-15, 20YA PRH-15, 20YA-L 21S4 Way valve MF1 Operate YES Electrical Operation Flow ChartsMC Operate MF2 Operate OFF Safety Device OFF? YES OFF 52C OFF MC Stop MF2 Stop RL on CH on Service CallMF1 Operate Start Power on Start Power on Refrigerant Schematics PR-5YCPR-8, 10, 15, 20YC PRH-8, 10, 15, 20YA PRH-8, 10,15,20YA-L Accessory Availability Safety & Control DevicesElectrical Physical DataRooftop Package AIR Cooled Heatpump and Cooling only Units Installation ClearancesRoof Mounting Drain piping Duct WorkElectrical Wiring Final ChecksTrial Operation Check Points for Operation Instructions for USEFingermarks MaintenanceTroubleshooting Preparing for Operation After Prolonged ShutdownPreparing for Prolonged Shutdown Specification Guidelines Memo Data Book PR,PRH Mitsubishi Electric Corporation

20-L, 8, PRH-5, 15, 10 specifications

Mitsubishi Electronics has long been a prominent player in the field of industrial automation, and their PRH series of smart human-machine interfaces (HMIs) is a testament to their innovative approach. The PRH-5, PRH-10, PRH-15, and the PRH-5,8 models exemplify the brand’s commitment to providing advanced technologies that enhance user interaction and facilitate the management of complex systems.

One of the main features of the PRH series is its high-resolution touch screen display, which provides clear and vibrant visuals for monitoring and controlling machinery. The screens offer exceptional clarity, making it easier for operators to interpret data and respond to system alerts promptly. The multi-touch capabilities allow for intuitive navigation, enhancing the user experience significantly.

The PRH series is equipped with robust communication technologies, including support for various industrial protocols such as MODBUS, Ethernet/IP, and Profinet. This flexibility enables seamless integration with a wide range of devices and systems, allowing for centralized control and monitoring of operations. Such interoperability is vital in modern manufacturing and process industries where diverse equipment needs to work harmoniously.

Another significant characteristic of the PRH series is its advanced data logging capabilities. These HMIs are designed to collect and store critical operational data, providing insights that can be analyzed for performance optimization and predictive maintenance. This feature is essential for minimizing downtime and ensuring that manufacturing processes operate at peak efficiency.

In terms of design, the PRH-5, PRH-10, PRH-15, and PRH-5,8 models feature a sleek and compact profile, making them suitable for installation in various environments, even where space is limited. They are built to withstand harsh industrial conditions, ensuring reliability and durability over long periods of use.

User-friendly software tools accompany the PRH series, enabling easy customization and programming of the interface to suit specific operational needs. Mitsubishi Electronics focuses on ensuring that users, regardless of their technical skills, can configure and manage the HMIs effectively.

In summary, Mitsubishi Electronics' PRH-5, PRH-10, PRH-15, and PRH-5,8 models represent the forefront of HMI technology. With high-resolution displays, extensive communication support, robust data logging capabilities, and user-friendly design, these devices are perfectly equipped to meet the challenges of modern industrial automation.