Mitsubishi Electronics 20 PRH-5, 20-L, 8, 10, 15 manual Descriptions, Mechanical Specifications

Page 7

DESCRIPTIONS

MITSUBISHI ELECTRIC Rooftop Air Conditioners Series PR,PRH,RPH-L are available in a wide range of sizes and models to enable the designer to select the best model for each application.

The complete range has been designed for outdoor installation, and the units are provided with the latest technological features to ensure economical, reliable and comfortable ducted type air conditioning.

All series units are completely assembled, wired and strictly tested at the factory. They consist of a

compressors, air-cooled condensers, evaporator fans, condenser fans and auxiliary and control equipment, completely packaged in a water-proof enclosure.

With the development of all series demands for such features as light weight, compactness, increased capacity, appropriate static pressure , air flow control, and having flexibility of inter-facing energy saving electronic controls Mitsubishi Electric have met market expectations.

MECHANICAL SPECIFICATIONS

General

All units are factory assembled, piped, internally wired and fully charged with R-22. They are also tested and checked under a strict quality control system in the factory. All units are designed for outdoor rooftop or ground level installation. Exterior surfaces of all units are phosphatized, zinc-coated steel with acrylic resin primer and ivory white baked enamel finish.

Condenser Coils

Unnecessary power input due to higher discharge pressure is avoided by high performance designs of cross-finned coils. Condenser coils are made of 9.52mm OD, 0.35mm thick seamless copper tubes mechanically bonded to 0.12mm thick aluminium plate fins. Each coil is factory pressure and leak tested at 3.3MPa.

Refrigeration Controls

Refrigeration controls include condenser fan, evaporator fan and compressor contactor. Each circuit of the unit has a separate set of refrigeration controls. PR, PRH,PRH-L-15,20 units have two independent circuits.

Evaporator Fans

Belt-drive, forward curved, centrifugal type fans made of galvanized steel are used to deliver an accurate airflow at low noise level.

Compressors

All units have high efficiency type hermetic line starting compressors. Compressors are equipped with thermal overload protector, overcurrent relay and high pressure protection controls. Crankcase heaters are standard .

Condenser Fan

This direct-drive propeller fan is dynamically balanced, to ensure smooth airflow. A weather- proof three-phase squirrel cage induction motor is used to drive the condenser fan.

Evaporator Coils

Highly efficient cross-finned coils are applied to provide a larger cooling capacity with low air speed on the coil. Coils are made of 9.52mm OD and 0.35mm thick seamless copper tubing mechanically bonded to 0.12mm thick aluminium fins and are factory leak tested at a pressure of 3.3MPa. They are provided with strainers attached to the capillary tubes to further ensure a clean system.

- 6-

Image 7 Contents
Heat Pump Data BookContents For correct installation Safety for USEDo not wash the unit with water Complete Line UP High Sensible Cooling Capacity FeaturesDescriptions Mechanical SpecificationsPRH PRH-L Typical Installation ExampleGross SpecificationsCooling Electrical DataHeating PR-5YC PRH-5YA-L Capacity TablesCooling Capacity Nominal Air FlowPR-5YC,PRH-5YA,PRH-5YA-L Factor for Various Air FlowRange PRH-5YA Heating Capacity Nominal Air FlowPRH-5YA,PRH-5YA-LPR-8YC PRH-8YA-L PRH-8YA Cooling Capacity Nominal Air FlowPR-8YC,PRH-8YA,PRH-8YA-LPR-8YC PRH-8YA-L Heating Capacity Nominal Air FlowPRH-8YA,PRH-8YA-LPRH-8YA PR-10YC PRH-10YA-L PRH-10YA Cooling Capacity Nominal Air FlowPR-10YC,PRH-10YA,PRH-10YA-LPRH-10YA-L Heating CapacityPRH-10YA PR-15YC PRH-15YA-L PRH-15YA Cooling Capacity Nominal Air FlowPR-15YC,PRH-15YA,PRH-15YA-LPRH-15YA PR-15YC PRH-15YA-LPR-20YC PRH-20YA-L PRH-20YA Cooling Capacity Nominal Air FlowPR-20YC,PRH-20YA,PRH-20YA-LPRH-20YA PRH-20YA-LPRH-YA-L Operation rangePR-YC PRH-YARpm FAN PerformanceOperation range Fan speed Pressure Pulley outside dimensions are shown below Unit mm PR-5YC PRH-5YA PRH-5YA-L PR-8YC PRH-8YA PRH-8YA-L NC CurvesPR-15YC PR-10YCPR-20YC Outline DimensionsPR-15,20YC PRH-15, 20YA PRH-15, 20YA-L PR-8,10YC PRH-8, 10YA PRH-8, 10YA-LPR-5, 8, 10YC Standard Wiring DiagramsPR-15, 20YC Standard Special Order K Control PR-5, 8, 10YCInternal Protector Special Order LOW TemperaturePR-15, 20YC 50Hertz Special Order K Control & LOW TemperaturePRH-5, 8, 10YA-L Standard PRH-5, 8, 10YAPRH-15, 20YA-L Standard PRH-5, 8, 10YA PRH-5, 8, 10YA-L 10YA PRH-15, 20YA PRH-15, 20YA-L 21S4 Way valve MF1 Operate YES Electrical Operation Flow ChartsMC Operate MF2 Operate OFF Safety Device OFF? YES OFF 52C OFF MC Stop MF2 Stop RL on CH on Service CallMF1 Operate Start Power on Start Power on PR-5YC Refrigerant SchematicsPR-8, 10, 15, 20YC PRH-8, 10, 15, 20YA PRH-8, 10,15,20YA-L Accessory Availability Safety & Control DevicesElectrical Physical DataRooftop Package AIR Cooled Heatpump and Cooling only Units Clearances InstallationRoof Mounting Drain piping Duct WorkFinal Checks Electrical WiringTrial Operation Check Points for Operation Instructions for USEFingermarks MaintenancePreparing for Operation After Prolonged Shutdown TroubleshootingPreparing for Prolonged Shutdown Specification Guidelines Memo Data Book PR,PRH Mitsubishi Electric Corporation