Mitsubishi Electronics 15, 20-L, 20 PRH-5, 8, 10 manual Complete Line UP

Page 5

A COMPLETE LINE UP

PR-5YC

PRH-5YA

PRH-5YA-L

(PRH ONLY)

Cooling capacity Heatling capacity

14,000

kcal/h

13,000

kcal/h

55,600

BTU/h

51,600

BTU/h

16.3

kW

15.1

kW

PR-8YC

PRH-8YA

PRH-8YA-L

(PRH ONLY)

Cooling capacity Heatling capacity

20,500

kcal/h

19,800

kcal/h

81,300

BTU/h

78,600

BTU/h

23.8

kW

23

kW

PR-10YC

PRH-10YA

PRH-10YA-L

(PRH ONLY)

PR-15YC

PRH-15YA PRH-15YA-L

Cooling capacity

Heatling capacity

25,500 kcal/h

27,500 kcal/h

101,200 BTU/h

109,100 BTU/h

29.7 kW

32 kW

(PRH ONLY)

Cooling capacity Heatling capacity

39,800 kcal/h

39,100 kcal/h

157,900 BTU/h

155,100 BTU/h

46.3 kW

45.5 kW

 

 

 

PR-20YC

 

PRH-20YA

 

 

PRH-20YA-L

 

(PRH ONLY)

Cooling capacity Heatling capacity

52,300 kcal/h

52,600 kcal/h

207,500 BTU/h

208,700 BTU/h

60.8 kW

61.2 kW

- 4 -

Image 5 Contents
Heat Pump Data BookContents For correct installation Safety for USEDo not wash the unit with water Complete Line UP High Sensible Cooling Capacity FeaturesDescriptions Mechanical SpecificationsPRH PRH-L Typical Installation ExampleGross SpecificationsHeating Electrical DataCooling Cooling Capacity Nominal Air FlowPR-5YC,PRH-5YA,PRH-5YA-L Capacity TablesFactor for Various Air Flow PR-5YC PRH-5YA-LRange PRH-5YA Heating Capacity Nominal Air FlowPRH-5YA,PRH-5YA-LPR-8YC PRH-8YA-L PRH-8YA Cooling Capacity Nominal Air FlowPR-8YC,PRH-8YA,PRH-8YA-LPRH-8YA Heating Capacity Nominal Air FlowPRH-8YA,PRH-8YA-LPR-8YC PRH-8YA-L PR-10YC PRH-10YA-L PRH-10YA Cooling Capacity Nominal Air FlowPR-10YC,PRH-10YA,PRH-10YA-LPRH-10YA Heating CapacityPRH-10YA-L PR-15YC PRH-15YA-L PRH-15YA Cooling Capacity Nominal Air FlowPR-15YC,PRH-15YA,PRH-15YA-LPRH-15YA PR-15YC PRH-15YA-LPR-20YC PRH-20YA-L PRH-20YA Cooling Capacity Nominal Air FlowPR-20YC,PRH-20YA,PRH-20YA-LPRH-20YA PRH-20YA-LPR-YC Operation rangePRH-YA PRH-YA-LRpm FAN PerformanceOperation range Fan speed Pressure Pulley outside dimensions are shown below Unit mm PR-5YC PRH-5YA PRH-5YA-L PR-8YC PRH-8YA PRH-8YA-L NC CurvesPR-15YC PR-10YCPR-20YC Outline DimensionsPR-15,20YC PRH-15, 20YA PRH-15, 20YA-L PR-8,10YC PRH-8, 10YA PRH-8, 10YA-LPR-5, 8, 10YC Standard Wiring DiagramsPR-15, 20YC Standard Special Order K Control PR-5, 8, 10YCInternal Protector Special Order LOW TemperaturePR-15, 20YC 50Hertz Special Order K Control & LOW TemperaturePRH-5, 8, 10YA-L Standard PRH-5, 8, 10YAPRH-15, 20YA-L Standard PRH-5, 8, 10YA PRH-5, 8, 10YA-L 10YA PRH-15, 20YA PRH-15, 20YA-L 21S4 Way valve MC Operate MF2 Operate OFF Safety Device OFF? YES Electrical Operation Flow ChartsOFF 52C OFF MC Stop MF2 Stop RL on CH on Service Call MF1 Operate YESMF1 Operate Start Power on Start Power on PR-8, 10, 15, 20YC Refrigerant SchematicsPR-5YC PRH-8, 10, 15, 20YA PRH-8, 10,15,20YA-L Accessory Availability Safety & Control DevicesElectrical Physical DataRooftop Package AIR Cooled Heatpump and Cooling only Units Roof Mounting InstallationClearances Drain piping Duct WorkTrial Operation Electrical WiringFinal Checks Check Points for Operation Instructions for USEFingermarks MaintenancePreparing for Prolonged Shutdown TroubleshootingPreparing for Operation After Prolonged Shutdown Specification Guidelines Memo Data Book PR,PRH Mitsubishi Electric Corporation