MICROPROCESSOR CONTROL
1.OUTLINE OF MICROPROCESSOR CONTROL
INPUT to remote controller
Remote controller board
OUTPUT to remote controller
●
●
●Thermostat setting.
●TIMER mode
●
●AUTO Vane selector (AIR DISCHARGE) switching.
●TEST RUN switching.
●CHECK mode switching.
(Self diagnostic trouble shooting)
●Processes and transmits orders.
●Indication LCD lights.
COOL CHECK | TEST | ˚F | |
| MODEL | RUN | |
DRY | ˚C | ||
SELECT |
| STOP AMPM | |
|
| ||
AUTO FAN | SWING |
| |
FAN |
| START AMPM | |
|
| ||
HEAT NOT AVAILABLE |
|
ON/OFF TEMP
Indoor unit
INPUT from indoor unit
●Room temperature thermistor (RT1)
●Pipe temperature thermistor (RT2)
OUTPUT to indoor unit
●Auto vane’s angle setting.
●Booster heater
●Emergency stop.
Independent Control of
Outdoor Unit
●Compressor protection device working
●Defrosting
●Fan speed control.
●Crankcase heater control
●Self diagnostic function
Indoor controller board
●Receives orders from remote controller and tem- perature data from indoor unit.
●Processes orders and data.
●Controls indoor and outdoor operation.
●Self diagnostic function.
wSystem control operation.
wEmergency operation.
wSet by dip switch on indoor controller board.
1 | 2 | 3 |
|
|
| unit |
|
Outdoor unit |
| outdoorto |
|
Polar |
|
|
|
12VDC |
| OUTPUT | ● Compressor and |
|
|
| |
|
|
| outdoor fan : ON- |
|
|
| OFF |
|
|
| ● Operation mode |
|
|
| change :COOL- |
1 |
|
| HEAT. |
2 |
|
|
|
3 |
|
|
|