Electrolux EI36WC60GS, EI30WC60GS Making the electrical connections, Mounting the glass canopy

Page 13

Installing the hood

13

 

Making the electrical connections

Electrical Shock Hazard

Warning: Turn off power at the service panel before wiring this unit.

120 VAC, 15 or 20 Amp circuit required.

ELECTRICAL GROUNDING INSTRUCTIONS

THIS APPLIANCE IS FITTED WITH AN ELECTRICAL JUNCTION BOX WITH 3 WIRES, ONE OF WHICH (GREEN/YELLOW) SERVES TO GROUND THE APPLIANCE. TO PROTECT YOU AGAINST ELECTRIC SHOCK, THE GREEN AND YELLOW WIRE MUST BE CONNECTED TO THE GROUNDING WIRE IN YOUR

HOME ELECTRICAL SYSTEM, AND IT MUST UNDER NO CIRCUMSTANCES BE CUT OR REMO- VED.

Failure to do so can result in death or electrical shock.

Remove junction box cover and knockout on the top left side.

Knockout

Junction box cover

Metal electrical conduit

House wiring

U.L. listed wire nut

Run black (live), white (neutral), and green (earth) wires (#14 AWG) according to the National Electrical Code or CSA Standards and local codes and ordinances in 1/2” conduit from power supply to j-box.

Connect black, white, and green wires from power supply to black, white, and green/yellow wires in j-box respectively.

These connections should be done always making reference to the electrical diagram found inside the hood.

Close j-box cover and reapply screws.

Mounting the glass canopy

With the hood mounted on the wall slide the glass canopy over the glass supports.

Insert the glass brackets.

Insert two screws into the bracket holes, drive the screws by hand.

If not already done, install 1/2” conduit connector in j-box.

Image 13 Contents
Installation, Use & Care Guide Please read and save this guide Table of contentsKeep a record for quick reference Questions?Important Safety Instructions Read and Save These Instructions Electrical requirements Electrical & Installation requirementsList of Materials Optional accessoriesParts Included with your Hood Tools/Materials requiredInstalling preparation Installing the hoodWall framing for adequate support Removing the packagingDuctwork and wiring locations Ductwork installation guidelinesExamples of possible ducting Mounting the duct cover bracket House wiring locationCeiling ducting Wall ductingMounting the hood Install framing for hood supportIMPORTANT- Framing must be capable of supporting 100 lbs Installing the hood Air deflector installation Recirculating accessories Connecting the ductworkMounting the glass canopy Making the electrical connections120 VAC, 15 or 20 Amp circuit required Failure to do so can result in death or electrical shockMounting the duct cover Features Control buttons Special functions For Best results Lights Care and cleaningFilters Cleaning Charcoal filter placement Recirculating accessoriesOptional Charcoal Filters Hood SurfaceRESPONSIBILITIESresponsible for the items listed below Exclusions This warranty does not cover the followingElectrolux Home Products North America