Electrolux EI36WC60GS, EI30WC60GS Electrical & Installation requirements, Electrical requirements

Page 5

Important safety Instructions - Electrical & Installation

5

requirements

READ AND SAVE THESE INSTRUCTIONS

 

Electrical & Installation requirements

 

Electrical requirements

IMPORTANT

Observe all governing codes and ordinances.

It is the customer’s responsibility:

To contact a qualified electrical installer.

To assure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No.0-M91 - latest edition** and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Do not ground to a gas pipe.

Check with a qualified electrician if you are not sure range hood is properly grounded.

Do not have a fuse in the neutral or ground circuit.

IMPORTANT

Save Installation Instructions for electrical inspector’s use.

The range hood must be connected with copper wire only.

The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit.

Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edi- tion*, or CSA Standards C22.1-94, Canadian Electri- cal Code Part 1 and C22.2 No. 0-M91 - latest edi- tion** and all local codes and ordinances.

A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box).

Copies of the standards listed may be obtained from:

*National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269

**CSA International 8501 East Pleasant Valley Road Cleve- land, Ohio 44131-5575

Before installing the hood

1.For the most efficient air flow exhaust, use a straight run or as few elbows as possible.

Vent unit to outside of building, only.

2.At least two people are necessary for installation.

3.The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall.

4.Do not use flex ducting.

5.COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

6.Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement.

The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area.

Image 5 Contents
Installation, Use & Care Guide Please read and save this guide Table of contentsKeep a record for quick reference Questions?Important Safety Instructions Read and Save These Instructions Electrical requirements Electrical & Installation requirementsList of Materials Optional accessoriesParts Included with your Hood Tools/Materials requiredInstalling preparation Installing the hoodWall framing for adequate support Removing the packagingExamples of possible ducting Ductwork installation guidelinesDuctwork and wiring locations Mounting the duct cover bracket House wiring locationCeiling ducting Wall ductingIMPORTANT- Framing must be capable of supporting 100 lbs Install framing for hood supportMounting the hood Installing the hood Air deflector installation Recirculating accessories Connecting the ductworkMounting the glass canopy Making the electrical connections120 VAC, 15 or 20 Amp circuit required Failure to do so can result in death or electrical shockMounting the duct cover Features Control buttons Special functions For Best results Filters Care and cleaningLights Cleaning Charcoal filter placement Recirculating accessoriesOptional Charcoal Filters Hood SurfaceElectrolux Home Products North America Exclusions This warranty does not cover the followingRESPONSIBILITIESresponsible for the items listed below