Electrolux FCW 300, FCW 200 manual Defrosting & Cleaning Procedure

Page 10

3. HOW TO USE

7.

If the cabinet temperature does not reach the required low level of 2-3 days, the freezer-thermostat setting can be increased to a higher setting by turning its knob clockwise.

8.

After storing the vaccines, keep the lid properly closed and locked (fig. 13).

Fig 13.

4. DEFROSTING & CLEANING

DEFROSTING & CLEANING

The moisture in the air, which enters the appliance due to lid opening (and also may be due to defective lid-gasket or door alignment) is attracted by the cold surfaces inside the appliance. So, formation of frost and ice occurs on the walls. When the frost layer is 1 /4" to 1 /2" (6-12 mm) thick, it is time for `defrosting' the appliance.

MOST IMPORTANT:

Before defrosting the appliance, the vaccines preserved in it will have to be removed and stored temporarily in other working freezer.

If a second appliance is not available, the vaccines will have to be preserved in Cold-Box or Vaccine carrier, properly lining the same with frozen ice packs, such that the vaccine temperature remains within the recommended storage temperature during the defrosting of the appliance.

DEFROSTING & CLEANING PROCEDURE

1.

Switch OFF the power supply to the appliance and remove the plug of its power supply cord from the wall socket.

2.

Prepare the temporary storage and transfer the vaccines and preserve them properly with care.

10

Image 10
Contents USER’s Manual FCW 200 ** FCW Index 13-14Thermometer POWER-SUPPLY ArrangementProduct Description Locking SystemInstallation Location a fig Location C fig Temperature Control Control Panel OPENING/CLOSING the LIDDefrosting & Cleaning Defrosting & Cleaning ProcedureDefrosting & Cleaning Weekly DailyMonthly Trouble Shooting Appliance is not WorkingIf the Appliance is to be Shut Down for Transportation ETC Abnormal Noise in the ApplianceFor Storing Vaccines FCW 200 Vaccine Loading FCW 300 Vaccine Loading None