viking range corporation | D3 Downdraft Ventilators |
|
|
inStaLL eLectricaL Wiring
Interior Blower Installation
! | caUtion: all electrical wiring should be done |
by a qualified person(s) in accordance with all | |
applicable codes and standards. |
1.Mount a standard wiring box, with
2.Run appropriate power cable into cabinet and connect it to receptacle.
3.Plug the downdraft's power cord into the outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.
inStaLL cooktop
Exterior Blower Installation
! | caUtion: all electrical wiring should be done |
by a qualified person(s) in accordance with all | |
applicable codes and standards. |
1.Mount a standard wiring box, with
2.Run appropriate power cabinet into cabinet and connect it to electrical box and receptacle.
3.Exterior blower may not exceed 6.0 amp rating.
4.Run
5.Connect downdraft wiring to power cable from remote blower. Wire black to black, white to white, and green to green or bare wire.
6.Replace wiring box cover.
7.Plug the downdraft's power cord into outlet. Make sure that the power cord is routed away from the heat generated by the cooktop.
All Units
"R" MODEL
DOWNDRAFT
1. Align the cooktop with the downdraft and fasten cooktop in place.
note: Accurate alignment of cooktop and downdraft is necessary to ensure that there is no interference when air vent is raised and lowered.There should be a gap of 1/32" - 1/16" between the back of the cooktop and the front of the downdraft cover.
REMOTE
CONTROL
COUNTERTOP
note:
The downdraft remote control must be mounted into the coun- tertop, at least 4" from cook top or range top edge.
8