D3 Downdraft Ventilators

 

 

pLan tHe Wiring

Interior Blower Installation

1.The Interior Downdraft Blower system draws 4 AMPS and requires a 120 VAC, 60 Hz circuit.

2.The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.

iMportant - Location oF eLectricaL oUtLet:

If Model RDIPR101RSS is being installed in a 30" wide

cabinet...

or Model RDIPR161RSS is being installed in a 36" wide

cabinet...

or Model RDIPR151RSS is being installed in a 45" wide

cabinet...

...the outlet cannot be located on the back wall of cabinet.

In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:

mount the electrical box to a side wall or cabinet floor

- at least 12 inches from the back wall.

mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft Then provide a clearance hole in the back wall of the cabinet.

prepare tHe DoWnDraFt

Exterior Blower Installation

1.The Exterior Downdraft Blower system draws 6 AMPS and requires a 120 VAC, 60 Hz circuit.

2.The downdraft has a 2 ft. long power cord with a 3-pronged plug. Plan to provide a grounded outlet in a location which will allow the unit’s power cord to reach.

iMportant - Location oF eLectricaL oUtLet:

If Model RDIPR101RSS is being installed in a 30" wide

cabinet...

or Model RDIPR161RSS is being installed in a 36" wide

cabinet...

or Model RDIPR151RSS is being installed in a 45" wide

cabinet...

...the outlet cannot be located on the back wall of cabinet.

In these cases, the width of the downdraft covers nearly the entire width of the back wall of the cabinet. So you must either:

mount the electrical box to a side wall or cabinet floor

- at least 12 inches from the back wall.

mount the electrical box to a wall stud behind the cabinet - where it will not be covered by the downdraft Then provide a clearance hole in the back wall of the cabinet.

pLeaSenote:External blowers must be hard-wired using locally- supplied wire and connected to the downdraft plug (included).

Interior Blower Installation

The downdraft is shipped without a blower. Purchase a Model VIDV500 Interior Blower and mount it to the downdraft as follows:

1.Place the downdraft on its back on a table of flat work surface.

2.Remove the 4 nuts and 2 clamp channels.

3.Remove 2 screws and the gear motor cover.

4.Carefully position the blower under the bottom flange of the downdraft with the 3¼" x 10" discharge pointed in the desired direction.

5.Connect motor plug.

6.Replace the gear motor cover and 2 sheet metal screws.

7.Replace the 2 clamp channels and start the 4 nuts, do not tighten.

8.Slide blower left of right to desired position. Use cover plate (supplied) to close up any open space.

9.Tighten 4 nuts to secure top of blower. Use additional screws (supplied) through bottom flange to secure bottom in blower.

3¼" X 10"

DISCHARGE

NUTS

BLOWER

CLAMP

CHANNELS

SCREWS

 

 

 

 

COVER

GEARMOTOR

MOTOR

PLATE

COVER

PLUG

 

 

 

ADDITIONAL

 

 

SCREWS

 

BOTTOM

5

FLANGE

 

Image 5
Contents MoDeL WiDtH IntenDeD For DoMeStic cooking onLYEvacuate and Call the Fire Department To reDUce tHe riSk oF a range top greaSe Fire PLanning Interior Blower Installation Exterior Blower Installation Take MeaSUreMentS All UnitsCalculation.3 PLan tHe DUctWorkSiDe vieW DoWnDraFt WitH ViDv500 Interior BLoWer PLan tHe caBinet cUtoUtS Prepare tHe DoWnDraFt PLan tHe WiringInterior Blower Installation CUt coUntertop opening MoUnt tHe Unit InStaLL DUctWorkBeFore cUtting HoLe CaBinet For DUctWork Ing, or plumbingInStaLL cooktop InStaLL eLectricaL WiringBy a qualified persons in accordance with all Applicable codes and standardsInStaLLation oF reMote controL SWitcH Backside Remote Switch Template Operation OptionaL reMote controL paDUSe anD care MoDeL DeScriptionBUILT-IN Rear Downdraft WARRantY MoDÈLe LargeUr VentiLateUr vendu séparément DeStiné À La cUiSine DoMeStiQUe SeULeMent AvertiSSeMentTous les appareils PréparationPriSe DeS MeSUreS Préparation DeS conDUitS PriSe DeS MeSUreS SUiteSortie À gaUcHe Préparation DU DécoUpage De L’arMoireSortie À Droite CONDUITS, assurez-vous que lesPréparation De La Hotte Préparation DU cÂBLageDécoUpage DU coMptoir Modèle DE Ventilateur Dimensions VIDV500Tous les modèles Tion Ronde DETuyaux de nuisent pas InStaLLation De L’UnitéInStaLLation DeS conDUitS SUrFace De cUiSSon InStaLLation De LaCÂBLage éLectriQUe BorD DU coMptoir InStaLLation De La téLécoMManDeArrière DU Gabarit DE LA Télécommande FonctionneMent TéLécoMManDeS en optionUtiLiSation et entretien MoDÈLe DeScriptionGarantie DeS HotteS encaStréeS De D3