LOCATION

The equipment area must be kept free and clear of combustible substances.

Installation clearances:

COMBUSTIBLE

NON-COMBUSTIBLE

 

CONSTRUCTION

CONSTRUCTION

Back:

6" (152 mm)

0"

Right Side:

10" (254 mm)

0"

Left Side:

10" (254 mm)

0"

The installation location must allow adequate clearances for servicing and proper operation. A minimum front clearance of 35" (889 mm) is required.

The ranges are suitable for installation on combustible floors when 6" (152 mm) adjustable legs or casters are used. When legs or casters are removed, use only on noncombustible floors, curb, or platform, with front appliance base projecting 3" (76 mm) beyond curb or platform.

The range(s) must be installed so that the flow of combustion and ventilation air will not be obstructed. Adequate clearance for air openings into the combustion chamber(s) must be provided. Make sure there is an adequate supply of air in the room to allow for combustion of the gas at the burners.

INSTALLATION CODES AND STANDARDS

Your Wolf Range must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (latest edition). This shall include but not be limited to: NFPA #54 Section 10.3.5.2 for Venting. Copies may be obtained from The American Gas Association Accredited Standards Committee Z223, @ 400 N. Capital St. NW, Washington, DC 20001 or the Secretary Standards Council, NFPA, 1 Batterymarch Park Quincy, MA 02169-7471.

NOTE: In the Commonwealth of Massachusetts

All gas appliances vented through a ventilation hood or exhaust system equipped with a damper or with a power means of exhaust shall comply with 248 CMR.

3.NFPA Standard # 96 Vapor Removal from Cooking Equipment, latest edition, available from the National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.CAN/CSA-B149.1 Natural Gas Installation (latest edition)

3.CAN/CSA-B149.2 Propane Installation Code (latest edition), available from the Canadian Gas Association, 178 Rexdale Blvd., Etobicoke, Ontario, Canada M9W 1R3

The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.

- 4 -

Image 4 Contents
Challenger XL Series Gas Restaurant Ranges Retain this Manual for Future USEImportant for Your Safety For Your SafetyOptional Field Installable Accessories InstallationAccessories DescriptionInstallation Codes and Standards LocationUnited States of America CanadaLEG/CASTER Assembly Range Series Legs to Install Casters to InstallTesting the GAS Supply System LevelingGAS Pressure Regulator GAS ConnectionsOperation Flue ConnectionsElectrical Connections ControlsBefore First USE OvensGriddles Lighting and Shutting Down Pilots TOP SectionsThermostatic Griddle Operating Suggestions Loading and Unloading the OvenDaily Cleaning CleaningOpen Top Maintenance & Adjustments Exterior CleaningStainless Steel LubricationTroubleshooting Service and Parts Information PrecautionsOven Problem Causes / Corrections TOP Burner Operation Problem Causes / CorrectionsForm F35696 Rev. E Remarques Possibles Problème Cuisson DE Surface LA DE Brûleur DépannageProblème Four Rechange DE Pièces ET L’ENTRETIEN DE Service Réglages ET EntretienLubrification Inoxydable AcierFrire à plaque la de Surface Nettoyage ’appareil de nettoyage le avant gaz le ÉteindreConventionnel four un dans Cuisson Découverts Brûleurs Fonctionnement DE SuggestionsPermanente veilleuse d’une Cuisson DE Surfaces Veilleuses DES Extinction ET Allumage Utilisation Première UNE AvantCommandes Fonctionnement’ÉVACUATION Conduit GAZ DU BranchementGAZ DE Pression DE Régulateur NivelageFigure la à qu’illustrés tels percés déjà Roulettes OU Pattes DES AssemblageNormes ET D’INSTALLATION Codes EmplacementCanada Au Unis-États AuxGénéralitês DéballageSécurité DE Mesure Importantes Sécurité DE Mesures’EMPLOI Mode ET D’INSTALLATION Mode