See additional warning information at front of this operator’s manual. WARNING

Do not attempt to use this equipment until you have thoroughly read the engine manufacturer’s manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.

• Do not touch electrically live parts or electrode with skin or wet clothing.

Insulate yourself from work and ground

Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.

• Use in open, well ventilated areas or vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.

Do not operate with doors open or guards off.

• Stop engine before servicing.

Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information at front of this operator’s manual.

-----------------------------------------------------------

In general, if the machine is to be grounded, it should be connected with a #8 or larger copper wire to a solid earth ground such as a metal water pipe going into the ground for at least ten feet and having no insulated joints, or to the metal framework of a building which has been effectively grounded. The U.S. National Electrical Code lists a number of alternate means of grounding electrical equipment. A machine grounding stud marked with the symbol Spark Arrester is provided on the front of the welder.

Spark Arrester

Some federal, state or local laws may require that gasoline engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard. The standard muffler included with this welder does not qualify as a spark arrester. When required by local regulations, the K894-1 arrester must be installed and properly maintained.

Machine GroundingCAUTION

Use of an incorrect arrester may lead to engine damage or performance loss.

-----------------------------------------------------------------------

Machine Grounding

Undercarriages

Because this por table engine driven welder or generator creates it’s own power, it is not necessary to connect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.).

To prevent dangerous electric shock, other equipment to which this engine driven welder supplies power must:

a.be grounded to the frame of the welder using a grounded type plug, or

b.be double insulated.

When this welder is mounted on a truck or trailer, it’s frame must be securely connected to the metal frame of the vehicle.

Where this engine driven welder is connected to premises wiring, such as that in your home or shop, it’s frame must be connected to the system earth ground. See further connection instructions in the section entitled Standby Power Connections in this manual, as well as the article on grounding in the latest U.S. National Electrical Code and the local code.

The recommended undercarriage for use with this equipment for in-plant and yard towing by a vehicle (1) is Lincoln’s K768-2. If the user adapts a non-Lincoln undercarriage, he must assume responsibility that the method of attachment and usage does not result in a safety hazard nor damage the welding equipment. Some of the factors to be considered are as follows:

(1) Consult applicable federal, state and local laws regarding specific requirements for use on public highways.

1.Design capacity of undercarriage vs. weight of Lincoln equipment and likely additional attachments.

2.Proper support of, and attachment to, the base of the welding equipment so there will be no undue stress to the framework.

3.Proper placement of the equipment on the undercarriage to ensure stability side to side and front to back when being moved and when standing by itself while being operated or serviced.