RANGER 9 AND 10LX /
WARNING
Do not operate with panels open. | Keep guards in place. |
Disconnect NEGATIVE | Keep away from moving parts. |
before servicing. | Only qualified personnel should install,use |
Do not touch electrically live parts. | or service this equipment. |
115V RECEPTACLE |
| |
RANGER |
|
|
14 PIN WIRE FEEDER | 6 PIN REMOTE | |
RECEPTACLE |
| |
|
| RECEPTACLE |
TO WORK | ELECTRODE |
|
K488 SG
CONTROL MODULE
INPUT CABLE
SPOOL GUN
ELECTRODE CABLE
TO WORK
TO CONTROL MODULE
CAUTION : BE SURE THAT CONTROL MODULE MODE SLIDE SWITCH IS IN THE "LINCOLN" (CONTACT CLOSURE) POSITION BEFORE ATTEMPTING TO OPERATE CONTROL MODULE. INCORRECT SWITCH POSITION COULD RESULT IN DAMAGE TO THE CONTROL MODULE AND/OR POWER SOURCE.
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.C. IF OPTIONAL K857 REMOTE OUTPUT CONTROL IS CONNECTED TO 6 PIN RECEPTACLE,PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.
N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.
CRM23615
M17902
– 35 –