Lincoln Electric IM511-D manual RANGER 9 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

Models: IM511-D

1 41
Download 41 pages 54.13 Kb
Page 33
Image 33
RANGER 9 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

RANGER 9 / LN-25 ACROSS THE ARC CONNECTION DIAGRAM

RANGER 9 / K867 / K775 / LN-7 CONNECTION DIAGRAMManual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual backgroundDo not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

14 PIN AMPHENOL

6 PIN AMPHENOL

OPTIONAL K444-1

TO WORK

ELECTRODE

REMOTE CONTROL

LN-25

WIRE FEEDER

WORK CLIP LEAD

TO WORK

TO WORK

ELECTRODE CABLE

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION.

N.D. WELDING TERMINALS SWITCH MUST BE PLACED IN "ALWAYS ON" POSITION.

12 - 16 - 93

M17090

RANGER 9 / K867 / K775 / LN-7 CONNECTION DIAGRAM

Manual backgroundManual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual background Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

1 4 P I N

A M P H E N O L

T O W O R K E L E C T R O D E

K867 UNIVERSAL

ADAPTER PLUG

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

CAUTION :

SPARE

 

 

82

 

 

81

N.D.

LN-7

42

 

WIRE

 

FEEDER

41

 

 

31

31

 

32

32

 

2

2

 

4

4

 

21

21

K291 OR K404

GND

 

GND

INPUT CABLE

 

GREEN

 

75

75

 

76

76

 

77

77

K775 OPTIONAL

N.E.

 

 

REMOTE CONTROL

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION. N.D. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

N.E. SPLICE LEADS AND INSULATE.

N.F. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

12 - 16 - 93

M17091