Image 36
TO LN-25 INPUT

RANGER 9 / LN-25 WITH 42 VOLT REMOTE OUTPUT CONTROL MODULE CONNECTION DIAGRAM

K915-1 AMPTROL ADAPTER FOR K799 HI-FREQ KITSManual background WARNING

Manual background Do not operate with panels open.

Manual background Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

Manual background Do not touch electrically live parts.

Manual background Keep guards in place.

Manual background Keep away from moving parts.

Manual background Only qualified personnel should install,use or service this equipment.

14PIN AMPHENOL

CAUTION :

TO WORK

ELECTRODE

TO LN-25 INPUT

CABLE PLUG

K626-XX INPUT CABLE ASSEMBLY

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.

12 - 16 - 93

M17214

K915-1 AMPTROL ADAPTER FOR K799 HI-FREQ KITS

WARNING

TURN THE ENGINE OR POWER SWITCH

 

 

OF THE WELDING POWER SOURCE "OFF"

 

BEFORE CONNECTING OR DISCONNECTING

ELECTRIC SHOCK

PLUGS TO WELDING POWER SOURCE.

can kill

POWER SOURCE

6-PIN PLUG

K963 HAND

AMPTROL

OR

K870 FOOT

AMPTROL

K915-1

AMPTROL

ADAPTER

6-SOCKET RECEPTACLE

-+

BYPASS *

 

 

CAPACITOR

 

 

KIT

 

 

 

ELECTRODE LEAD

*

HI-FREQ KIT

WORK SENSE LEAD

*

INPUT POWER *

 

THIS ADAPTER ALLOWS AN AMPTROL TO OPERATE A K799 HI-FREQ KIT WHILE REMOTELY CONTROLLING THE OUTPUT CURRENT OF A LINCOLN POWER SOURCE. (THE POWER SOURCE MUST BE EQUIPPED WITH A

6-PIN REMOTE CONTROL AMPHENOL CONNECTOR.) SEE THE HI-FREQ KIT AND POWER SOURCE INSTRUC- TION MANUAL FOR INFORMATION ON PROPER SWITCH AND CONTROL SETTINGS.

5-PIN PLUG

K799 HI-FREQ KIT

*SEE INSTRUCTIONS INCLUDED WITH HI-FREQ KIT FOR CONNECTION INFORMATION.

4-19-96D

S20909