RANGER 9 / K867 / LN-8 CONNECTION DIAGRAM
WARNING
Do not operate with panels open.
Disconnect NEGATIVE
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use or service this equipment.
14PIN AMPHENOL
TO WORK | ELECTRODE |
TO WORK
K867 UNIVERSAL
ADAPTER PLUG
ELECTRODE CABLE TO WIRE FEED UNIT
SPARE |
|
82 |
|
81 | N.C. |
42 |
|
41 |
|
31 | 31 |
32 | 32 |
2 | 2 |
4 | 4 |
21 | 21 |
GND | GND |
75 A
76 B
77 C
WIRE
FEEDER
K196
INPUT CABLE
CAUTION : | N.D. |
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITION. PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED " POSITION.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY. N.D. SPLICE LEADS AND INSULATE.
N.E. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.
12 - 16 - 93
M17094
RANGER 9 / LN-742 CONNECTION DIAGRAM
WARNING
Do not operate with panels open.
Disconnect NEGATIVE
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use or service this equipment.
14 PIN AMPHENOL
TO WORK | ELECTRODE |
TO LN-742 INPUT
CABLE PLUG
K592 CONTROL CABLE
ELECTRODE CABLE TO WIRE FEED UNIT
CAUTION :
TO WORK
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDER TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.D. PLACE IDLER SWITCH IN "AUTO" OR "HIGH" IDLE POSITION AS DESIRED.