Lincoln Electric IM511-D Warnin G, RANGER 9 / LN-7 CONNECTION DIAGRAM, To Work, Electrode Cable

Models: IM511-D

1 41
Download 41 pages 54.13 Kb
Page 34
Image 34
RANGER 9 / LN-7 CONNECTION DIAGRAM

RANGER 9 / LN-7 CONNECTION DIAGRAM

14PIN AMPHENOLTO LN-7 INPUT WARNING

K584-XX INPUT CABLE ASSEMBLY Do not operate with panels open.

ELECTRODE CABLE Disconnect NEGATIVE (-) BATTERY LEAD before servicing.

TO WORK Do not touch electrically live parts.

RANGER 9 TO K867 ADAPTER CONNECTION DIAGRAM Keep guards in place.

WARNING Keep away from moving parts.

TO WIRE FEED UNIT Only qualified personnel should install,use or service this equipment.

14PIN AMPHENOL

6PIN AMPHENOL

CAUTION :

TO WORK

ELECTRODE

TO LN-7 INPUT

CABLE PLUG

OPTIONAL K857

REMOTE CONTROL

K584-XX INPUT CABLE ASSEMBLY

ELECTRODE CABLE

TO WIRE FEED UNIT

TO WORK

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.

N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.

N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.

12 - 16 - 93

M17092

RANGER 9 TO K867 ADAPTER CONNECTION DIAGRAM

WARNING

Do not operate with panels open.

 

Keep guards in place.

Disconnect NEGATIVE (-) BATTERY LEAD

Keep away from moving parts.

before servicing.

 

Only qualified personnel should install,use

Do not touch electrically live parts.

 

or service this equipment.

14 PIN

 

N.C.

AMPHENOL

 

81

 

 

 

 

82

NOT USED ON RANGER POWER SOURCES

 

SPARE

 

K867 UNIVERSAL

2

CONNECT TOGETHER FOR

ADAPTER PLUG

4

N.D.

 

41

WELDING OUTPUT

 

42 VAC

 

42

 

N.E.

 

31

 

115 VAC

 

32

TO WORK ELECTRODE

 

GND

POWER SOURCE FRAME CONNECTION

 

ELECTRODE CABLE

21

WIRE FEEDER VOLTMETER CONNECTION

 

CONNECTS TO (WORK TERMINAL) OF POWER SOURCE

TO WIRE FEED UNIT

77

10K

TO WORK

76

REMOTE OUTPUT CONTROL

75

MIN.

CAUTION :

ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS PRE-SET AT THE FACTORY - DO NOT ADJUST ABOVE RPM SPECIFICATIONS LISTED IN

THE ENGINE WELDER OPERATING MANUAL.

N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.

N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.

N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY.

{

 

 

2

 

 

 

N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION

TO

RELAY TO CLOSE LEADS 2 & 4.

K867

 

 

 

 

4

 

 

 

N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.

TO WIRE FEEDER

12 - 16 - 93

M17093

– 32 –

Page 34
Image 34
Lincoln Electric IM511-D manual Warnin G, RANGER 9 / LN-7 CONNECTION DIAGRAM, Electrode Cable To Wire Feed Unit, To Work