RANGER 9 / LN-7 CONNECTION DIAGRAM
WARNING
Do not operate with panels open.
Disconnect NEGATIVE
Do not touch electrically live parts.
Keep guards in place.
Keep away from moving parts.
Only qualified personnel should install,use or service this equipment.
14PIN AMPHENOL
6PIN AMPHENOL
CAUTION :
TO WORK | ELECTRODE |
TO LN-7 INPUT
CABLE PLUG
OPTIONAL K857
REMOTE CONTROL
K584-XX INPUT CABLE ASSEMBLY
ELECTRODE CABLE
TO WIRE FEED UNIT
TO WORK
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. USE POLARITY SWITCH TO SET FOR DESIRED ELECTRODE POLARITY. POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION. PLACE WELDING TERMINALS SWITCH TO "REMOTELY CONTROLLED" POSITION.
N.B. WELDING CABLES MUST BE OF PROPER CAPACITY FOR THE CURRENT AND DUTY CYCLE OF IMMEDIATE AND FUTURE APPLICATIONS. SEE OPERATING MANUAL.
N.C. IF OPTIONAL REMOTE OUTPUT CONTROL IS USED, PLACE OUTPUT CONTROL SWITCH IN "OUTPUT CONTROL REMOTE" POSITIION. N.D. PLACE IDLER SWITCH IN "HIGH" IDLE POSITION.
12 - 16 - 93
M17092
RANGER 9 TO K867 ADAPTER CONNECTION DIAGRAM
WARNING | |||
Do not operate with panels open. |
| Keep guards in place. | |
Disconnect NEGATIVE | Keep away from moving parts. | ||
before servicing. |
| Only qualified personnel should install,use | |
Do not touch electrically live parts. |
| or service this equipment. | |
14 PIN |
| N.C. | |
AMPHENOL |
| ||
81 |
| ||
|
| ||
| 82 | NOT USED ON RANGER POWER SOURCES | |
| SPARE |
| |
K867 UNIVERSAL | 2 | CONNECT TOGETHER FOR | |
ADAPTER PLUG | 4 | N.D. | |
| 41 | WELDING OUTPUT | |
| 42 VAC | ||
| 42 | ||
| N.E. | ||
| 31 | ||
| 115 VAC | ||
| 32 | ||
TO WORK ELECTRODE |
| ||
GND | POWER SOURCE FRAME CONNECTION | ||
| |||
ELECTRODE CABLE | 21 | WIRE FEEDER VOLTMETER CONNECTION | |
| CONNECTS TO (WORK TERMINAL) OF POWER SOURCE | ||
TO WIRE FEED UNIT | 77 | 10K | |
TO WORK | 76 | REMOTE OUTPUT CONTROL | |
75 | MIN. |
CAUTION :
ANY INCREASE OF THE HIGH IDLE ENGINE RPM BY CHANGING THE GOVERNOR SETTING OR OVERRIDING THE THROTTLE LINKAGE WILL CAUSE AN INCREASE IN THE THE AC AUXILIARY VOLTAGE. IF THIS VOLTAGE GOES OVER 140 VOLTS, WIRE FEEDER CONTROL CIRCUITS MAY BE DAMAGED. THE ENGINE GOVERNOR SETTING IS
THE ENGINE WELDER OPERATING MANUAL.
N.A. WELDING CABLE MUST BE SIZED FOR CURRENT AND DUTY CYCLE OF APPLICATION.
N.B. USE POLARITY SWITCH TO SET DESIRED POLARITY, POSITION THE OUTPUT SELECTOR SWITCH TO A CV POSITION.
N.C. INSULATE EACH UNUSED LEAD INDIVIDUALLY. | { |
|
| 2 |
|
|
| ||
N.D. FOR WIRE FEEDERS THAT RETURN A SIGNAL FOR WELDING OUTPUT, USE ISOLATION | TO | |||
RELAY TO CLOSE LEADS 2 & 4. | K867 | |||
|
|
|
| 4 |
|
|
|
N.E. REFER TO POWER SOURCE INSTRUCTION MANUAL FOR MAXIMUM AUXILIARY CURRENT DRAW.
TO WIRE FEEDER
12 - 16 - 93
M17093