Gas type changing:
From natural gas to propane
It is necessary that all operations related with installation, adjustment or adaptation LP gas be performed by authorized personnel
of our Technical Service, and that the regulations in force, as well as the requisites of the gas companies, be followed.
IMPORTANT: Before you begin, turn off the gas and electricity supply to the appliance.
Before connecting up the appliance to the installation, first check that it has been adjusted for the type of gas that is to be supplied. Our cooktops are delivered from factory prepared to operate with the gas type indicated on the specifications plate.
The propane gas tank must be equipped with its own high pressure regulator in addition to the pressure regulator supplied with this unit.
Supply Pressure
Natural Gas - 7" wc (17.5 mbar) minimum. Propane Gas - 11" wc (27.4 mbar) minimum. The maximum supply pressure to this appliance shall not exceed 14" water column (34.9 mbar). This cooktop can be adapted to work
with LP gas. To do so, the following procedures must be completed:
A)Change of rapid,
T ABLE 1
Burner data
The burner must be used with the | GAS | NATURAL | PROPANE | ||
gases indicated on the |
| TYPE | |||
specifications plate. |
|
|
|
| |
Gas pressure for use |
|
| 6” | 10” | |
Burner | Burner tip marker |
| 138 | 91 | |
rapid | Consumption | Rated | BTU/hr | 9.800 | 9.800 |
| (Hs) |
|
|
|
|
Burner | Burner tip marker |
| 110 | 76 | |
semi- | Consumption | Rated | BTU/hr | 6.500 | 6.500 |
rapid | (Hs) |
|
|
|
|
Burner | Burner tip marker |
| 85 | 60 | |
auxiliar | Consumption | Rated | BTU/hr | 3.900 | 3.900 |
| (Hs) |
|
|
|
|
| Burner tip marker |
| 184/X | 129/ | |
Large | Consumption | Rated | BTU/hr | 20.000 | 20.000 |
(Hs) |
|
|
|
| |
|
|
|
| ||
Burner |
|
|
|
|
|
double | Distance "Y" inner |
|
|
| |
flame | bushing |
|
|
|
|
| Distance "Z" outer |
|
|
| |
| bushing |
|
|
|
|
|
|
|
|
|
|
1 - Remove the grates, covers and the main body of the burner.
2 - Change the burner tips using the spanner provided by our technical services department
(code 424699) and make sure that they are tightened all the way in order to ensure that they are correctly sealed. Figure 4.
The adjustment of primary air must not be performed on these burners.
Fig. 4