DeLonghi DEFSGG 36 warranty Flexible Connections, Rigid Pipe Connections, Leak Testing

Page 18

TEST POINT ADAPTER

The Test Point adapter is available from the After-Sales Service.

c)Any conversion required must be performed by your dealer or a qualified licensed plumber or gas service company. Please provide the service person with this manual before work is started on the range. (Gas conversions are the responsibility of the dealer or end user.)

d)This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with NATURAL gas.

e)Manifold pressure should be checked with a manometer and by operating as below detailed:

-Remove the injector from the front left burner and mount the proper test point adapter which is available from the After-Sales Service (see side figure and the

“OPERATIONS TO BE PERFORMED WHEN SUBSTITUTING THE INJECTORS” chapter).

-Turn the front left burner control knob to the maximum position ( position)

-Press the knob and keeping it pressed check the manifold pressure with a manometer; NATURAL gas requires 4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P.

-Incoming line pressure upstream from the regulator must be 1” W.C.P. higher than the manifold pressure in order to check the regulator.

-The regulator used on this range can withstand a maximum input pressure of 1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a step- down regulator will be required.

f)The appliance, its individual shut-off valve, and pressure regulator must be disconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 PSI (3.5 kPa).

g)The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).

 

3. Flexible Connections:

 

If local codes permit, CSA design-certified, flexible metal appliance connector is

 

recommended for connecting this range to the gas supply line. Do Not kink or damage

 

the flexible connector when moving the range. The pressure regulator has 1/2" NPT

Fig. 2.4

female pipe threads.You will need to determine the fittings required, depending on

the size of your gas supply line, flexible metal connector and shutoff valve.

 

4. Rigid Pipe Connections:

If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the range. All strains must be removed from the supply and fuel lines so range will be level and in line.

Use joint compounds and gaskets that are resistant to action of natural or propane gas on all male pipe threads.

Do not over tighten gas fitting when attaching to pressure regulator. Over tightening may crack regulator.

5. Leak Testing:

IMPORTANT: Leak testing of the appliance shall be conducted as follows:

After final gas connection is made, turn on manual gas valve and test all connections in gas supply piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas valves have to be closed.

In order to avoid property damage or serious personal injury, never use a Iighted match. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.

18

Image 18
Contents Double Oven GAS Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Tools Needed for InstallationReplacement Parts Electrical Grounding InstructionsInstallation Proximity to Side CabinetsGAS and Electric Connection 500 305 Fitting the Adjustable Feet Levelling the CookerMoving the Cooker Or the Island Trim It is mandatory to installAssembling the Backguard Backguard or the island trimANTI-TIP Stability Device Installation Instructions 28 15/16 735 mmManual Shut-off Valve fig Explosion HazardPressure Regulator Pressure Regulator Installation Step Step Step Pressure Regulator Installation Range Manifold Manifold male Pipe fittingLeak Testing Flexible ConnectionsRigid Pipe Connections Setting the Pressure Regulator fig Conversion to LP/PROPANE GASInjectors Table BurnersSetting the Burner Minimum Semirapid and triple ring burnersOven Burner Adjustment of the Oven Burner Minimum Left and Right Oven Electrical connection Recommended ground methodWiring Diagram TL2 TL3 TL4 TL1 PA1Page Page Cod ß6