PROXIMITY TO SIDE CABINETS

1.This range may be installed directly adjacent to existing 36" (914 mm) high base cabinets.

Range dimensions:

width: 35” 7/8 (911 mm)

depth: 23” 31/32 (609 mm)

height (without backguard / island trim): MIN 35” 7/16 (900 mm) MAX 37” 13/32 (950 mm)

backguard (height): 8” (203 mm)

island trim (height): 3” (76 mm)

Gas line opening:

Wall - 7” 15/32 (190 mm) from the floor; 15” 3/4 (400 mm) from the rear right side of the range.

Grounded outlet: the electric cord with 3-prong ground plug has a length of 72” (1830 mm). Grounded outlet should be located 20” 1/8 (511 mm) from the left side to centre of range and from 5” 1/8 (130 mm) to 7” 3/32 (180 mm) [depending on feet regulation] from the floor.

2.The range CANNOT be installed directly adjacent to side- walls, tall cabinets, tall appliances, or other side vertical sur- faces above 36” (914 mm) high.

There must be a minimum of 11” 13/16 (300 mm) side clear- ance from the range to such combustible surfaces TO THE LEFT or TO THE RIGHT above the 36” (914 mm) high coun- tertop.

IMPORTANT: One side (left or right) above the 36” (914 mm) high countertop must always be kept clear.

Installation with island trim: There must be a minimum of 12” (305 mm) clearance from the back of the island trim to such combustible surface on the back of the range above the 36” (914 mm) high countertop.

3.The maximum upper cabinet depth recommended is 13” (330

mm).Wall cabinet above the range must be a minimum of 30”

(762 mm) above the countertop for a width of minimum 35” 7/8 (911 mm): it has to be centred with the range. Side wall cabinets above the range must be a minimum of 18” (457

mm)above the countertop.

 

mm)

 

 

Backguard

 

23"

31/32

 

 

8"

(203

(609

 

mm)

 

 

 

 

(900 mm)

(950 mm)

 

 

 

MIN 35" 7/16

MAX 37" 13/32

 

 

 

35"

7/8

mm)

 

(911

Fig. 1.1a

Island trim

3"

(76mm)

23"

31/32

 

 

(609

 

 

 

mm)

 

 

 

(900 mm)

(950 mm)

 

 

 

MIN 35" 7/16

MAX 37" 13/32

 

 

 

35"

7/8

mm)

 

(911

Fig. 1.1b

6

Image 6
Contents Double Oven GAS Range ALL Ranges can TIP Data Plate Conversion Label Installation Instructions Tools Needed for InstallationReplacement Parts Electrical Grounding InstructionsInstallation Proximity to Side CabinetsGAS and Electric Connection 500 305 Fitting the Adjustable Feet Levelling the CookerMoving the Cooker Or the Island Trim It is mandatory to installAssembling the Backguard Backguard or the island trimANTI-TIP Stability Device Installation Instructions 28 15/16 735 mmManual Shut-off Valve fig Explosion HazardPressure Regulator Pressure Regulator Installation Step Step Step Pressure Regulator Installation Range Manifold Manifold male Pipe fittingLeak Testing Flexible ConnectionsRigid Pipe Connections Setting the Pressure Regulator fig Conversion to LP/PROPANE GASInjectors Table BurnersSetting the Burner Minimum Semirapid and triple ring burnersOven Burner Adjustment of the Oven Burner Minimum Left and Right Oven Electrical connection Recommended ground methodWiring Diagram TL2 TL3 TL4 TL1 PA1Page Page Cod ß6