SETTING THE BURNER MINIMUM

 

When switching from one type of gas to another, the minimum flow rate must also be

F

correct: the flame should not go out even when passing suddenly from maximum to

 

minimum flame.

 

 

To regulate the flame follow the instructions below:

 

Semirapid and triple ring burners

 

Light the burner

 

 

Set the gas valve to

position

 

– Remove the knob

 

 

– With a thin screwdriver pass by the hole of microswitch and turn the screw F until

 

 

adjustment is correct (fig. 2.7).

Fig. 2.7

 

 

 

Inside crown of DUAL burner

Light the DUAL burner

Set the gas valve to position

Remove the knob

Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).

Outside crowns of DUAL burner

Light the DUAL burner

Set the gas valve to position

Remove the knob

Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).

For LP/PROPANE gas, tighten the adjustment screws completely.

H

G

Fig. 2.8

21

Image 21
Contents Double Oven GAS Range ALL Ranges can TIP Data Plate Conversion Label Tools Needed for Installation Installation InstructionsElectrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationGAS and Electric Connection 500 305 Fitting the Adjustable Feet Levelling the CookerMoving the Cooker Assembling the Backguard It is mandatory to installOr the Island Trim Backguard or the island trim28 15/16 735 mm ANTI-TIP Stability Device Installation InstructionsManual Shut-off Valve fig Explosion HazardPressure Regulator Pressure Regulator Installation Step Step Step Range Manifold Manifold male Pipe fitting Pressure Regulator InstallationLeak Testing Flexible ConnectionsRigid Pipe Connections Conversion to LP/PROPANE GAS Setting the Pressure Regulator figBurners Injectors TableSemirapid and triple ring burners Setting the Burner MinimumOven Burner Adjustment of the Oven Burner Minimum Left and Right Oven Recommended ground method Electrical connectionTL2 TL3 TL4 TL1 PA1 Wiring DiagramPage Page Cod ß6