SETTING THE BURNER MINIMUM |
| ||
When switching from one type of gas to another, the minimum flow rate must also be | F | ||
correct: the flame should not go out even when passing suddenly from maximum to |
| ||
minimum flame. |
|
| |
To regulate the flame follow the instructions below: |
| ||
Semirapid and triple ring burners |
| ||
– | Light the burner |
|
|
– | Set the gas valve to | position |
|
– Remove the knob |
|
| |
– With a thin screwdriver pass by the hole of microswitch and turn the screw F until |
| ||
| adjustment is correct (fig. 2.7). | Fig. 2.7 | |
|
|
|
Inside crown of DUAL burner
–Light the DUAL burner
–Set the gas valve to position
–Remove the knob
–Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).
Outside crowns of DUAL burner
–Light the DUAL burner
–Set the gas valve to position
–Remove the knob
–Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).
For LP/PROPANE gas, tighten the adjustment screws completely.
H |
G |
Fig. 2.8 |