On the left hand of the screen, above the control panel, is the status panel. The status panel contains four lines of information, three of which are always displayed. The first line announces whether a SmarTrack® model is available or not (No Model or Model Ready). The second line reports the tracking mode (Standby, Step Track, SmarTrack®, NORAD Track, or INTELSAT Track). The third line displays alarm when alarms are present. If any alarm is present, the alarm status is red and flashing, indicating an alarm condition has occurred which the operator has not evaluated yet. (See Figure 4.) The fourth line in the status box will appear when a Hand Held Unit is attached or when the PC is in Monitor Only mode. Control is maintained by the Hand Held Unit or another Java application, an ADU, or M&C port. If line four is displayed, it will report in yellow the status message Hand Held or Monitor Only. (See Figure 5.)

Figure 4: Home Screen - System Is Initialized

Home Screen - Hand Held Connected

Figure 5 shows the Home Screen when a Hand Held Controller device has been connected to the antenna controller system. Whenever a Hand Held Controller device is directly connected to the antenna, the antenna controller, from the operators PC, displays are strictly monitoring displays. Notice that the Position / Jog screen and the Tracking screen buttons in the control panel are no longer available to the operator. All the information displayed on the screen is still valid and will reflect all actions that are exercised by the Hand Held Unit but the operator will not be able to make any modifications or position moves while the Hand Held Unit is connected. The Hand Held Unit has priority. Movement icons will still be displayed to the right of the Azimuth, Elevation, and Polarization value boxes to show when an axis is in motion.

14 of 51

System Screens

Image 14
Contents ACS3000 Antenna Control System OMACS3000 OMACS3000 List of Figures Revision History OverviewSummary System DescriptionOMACS3000 Motherboard Limit/Status Card LIM-2 Indicators Within the LMKVS-CPUMC-2 Description Microprocessor Card MPU-17Resolver To Digital Converter Card RES-2 Low Temperature BoardDual VFD Motor Drive Card MD-3 Antenna Display Unit Optional Power/Environmental Description LMKVS-CPUPower/Environmental Description Beacon Interface System Description LMKVS-CPU IP Setup Operator’s Computer SetupJava Plug In Installation Operator’s Computer IP AddressRegional Options Setup LMKVS-CPU Admin ApplicationHome Screen System Initialized ACS3000 ScreensHome Screen System Not Initialized Home Screen Hand Held Connected Home Screen System Is InitializedSet Time/IP Home Screen Hand Held Controller ConnectedInitialization Screens Initialization EntryTest Only Password Protection Screen Initialization Entry ScreenPre-Initialization Antenna Setup Test Only Password ScreenPre-Initialization Antenna Setup Initialize Site LocationAntenna Size Polarization Drive P/N Ratio Visible Satellites ComputedVerify Jog Direction Visible Satellites Computed ScreenVerify Az and El Hardware Limits Verify Jog Direction ScreenVerify Pol Hardware Limits Single Speed Pol Drive Hardware LimitsDual Speed Pol Drive Hardware Limits Single Speed Pol Hardware Limits ScreenSelect Base Satellite Dual Speed Pol Hardware Limits ScreenPeak on Base Satellite Select Base Satellite ScreenOMACS3000 Peak on Base Satellite Screen Automated Set Software Limits Automated Set Software Limits ScreenEnter Beacon Receiver Parameters DirectionReview Parameters Enter Tracking Parameters ScreenInitialization Complete Review Parameters ScreenNormal Operational Screens Position/JogTracking Control Position/Jog ScreenTracking Summary Satellite Table Screens Track Control ScreenSatellite Table Screen Satellite Table Button Right Click OptionWorking Satellite Table Screen Satellite Table ScreenSatellite Entry Edit Working Satellite Table ScreenLogs/Alarms Satellite Table Entry Edit ScreenLog/Alarms Button Right Click Display Log ScreenAlarm Screen Alarm and Events DescriptionsOMACS3000 OMACS3000 OMACS3000 Update Table Alarm ScreenCelestrack Web Site Norad Data Set Update Software Alternate Update Satellite Table Popup WindowUpdate Software Button OMACS3000

OMACS3000 specifications

Andrew OMACS3000 is a highly advanced multi-functional automation and control system designed to streamline operations in various industries, including manufacturing, utilities, and logistics. At its core, the OMACS3000 integrates cutting-edge technologies to enhance efficiency, improve precision, and facilitate real-time data monitoring.

One of the main features of the OMACS3000 is its modular architecture. This design allows users to customize the system according to specific operational needs, enabling them to scale up or down as necessary. The system can support a wide array of inputs and outputs, making it adaptable for different types of machinery and processes. The modular approach not only allows for easy upgrades but also minimizes downtime during maintenance or system changes.

Another significant characteristic of the OMACS3000 is its use of smart sensors and IoT connectivity. The system is equipped with advanced sensors that monitor various parameters such as temperature, pressure, and flow rates in real time. By leveraging IoT technology, the OMACS3000 can transmit data to a centralized management platform, allowing for in-depth analysis and streamlined decision-making. This connectivity facilitates predictive maintenance, reducing the risk of unexpected failures and optimizing maintenance schedules.

The OMACS3000 is also designed with user-friendly interfaces, featuring intuitive dashboards that provide operators with easy access to critical information. These dashboards allow users to track performance metrics, set alerts for abnormal conditions, and visualize data trends. By prioritizing user experience, the OMACS3000 empowers operators to make informed decisions quickly, thus improving overall operational efficiency.

In terms of security, the OMACS3000 incorporates robust cybersecurity measures to protect sensitive data and prevent unauthorized access. Advanced encryption protocols and user authentication mechanisms are employed to safeguard the system against potential threats, ensuring the integrity of operations.

Finally, the OMACS3000 is built to comply with international standards for safety and quality, making it suitable for global markets. Its adaptability, coupled with its comprehensive features and advanced technologies, positions the OMACS3000 as a leader in the automation and control systems landscape, paving the way for the future of efficient and reliable industrial operations.