Andrew OMACS3000 manual Satellite Table Screens, Track Control Screen

Page 36

11-APR-06

Rev E

OMACS3000

message for low signal will be issued but does not suspend antenna movement if the model is valid. The Smart Track model will become invalid after two days with no new valid peaks.

If NORAD track is selected the operator must ensure that the system time is correctly set to UTC time. The NORAD algorithm uses UTC to calculate the azimuth and elevation angles. The site location must also be accurate. Significant errors may result if time and location are not correct. NORAD is intended to help find a target. For antennas with beamwidths less than 0.25 degrees some signal loss may result from pointing errors if NORAD is used as the primary tracking mode.

If INTELSAT track is selected the operator must ensure that the system time is correctly set to UTC time. The INTELSAT algorithm uses UTC to calculate the azimuth and elevation angles. The site location must also be accurate. Significant errors may result if time and location are not correct. INTELSAT is intended to help find a target. For antennas with beamwidths less than 0.25 degrees some signal loss may result from pointing errors if INTELSAT is used as the primary tracking mode.

The operator must switch to Not Track before selecting a different track mode, meaning that the ACS3000 will not switch from Norad Tracking directly to Smart Tracking. The operator must select the No Track first before switching to Smart Tracking.

Figure 26: Track Control Screen

Satellite Table Screens

The operator may display the satellite table entries by selecting the Satellite Table button from the left control panel. The operator can right click on the Satellite Table button in the control panel to select a special test satellite table or to save the current satellite table to the PC. The test satellite table contains a limited number of satellites that can be used for test purposes but is not valid for normal operation. If the test table is loaded, the operator must update the satellite table prior to normal operation.

36 of 51

System Screens

Image 36
Contents ACS3000 Antenna Control System OMACS3000 OMACS3000 List of Figures Overview SummaryRevision History System DescriptionOMACS3000 Indicators Within the LMKVS-CPU MC-2 DescriptionMotherboard Limit/Status Card LIM-2 Microprocessor Card MPU-17Low Temperature Board Dual VFD Motor Drive Card MD-3Resolver To Digital Converter Card RES-2 Power/Environmental Description LMKVS-CPU Power/Environmental Description Beacon InterfaceAntenna Display Unit Optional System Description Operator’s Computer Setup Java Plug In InstallationLMKVS-CPU IP Setup Operator’s Computer IP AddressRegional Options Setup LMKVS-CPU Admin ApplicationACS3000 Screens Home Screen System Not InitializedHome Screen System Initialized Home Screen Hand Held Connected Home Screen System Is InitializedSet Time/IP Home Screen Hand Held Controller ConnectedInitialization Screens Initialization EntryTest Only Password Protection Screen Initialization Entry ScreenPre-Initialization Antenna Setup Test Only Password ScreenPre-Initialization Antenna Setup Initialize Site LocationAntenna Size Polarization Drive P/N Ratio Visible Satellites ComputedVerify Jog Direction Visible Satellites Computed ScreenVerify Az and El Hardware Limits Verify Jog Direction ScreenVerify Pol Hardware Limits Single Speed Pol Drive Hardware LimitsDual Speed Pol Drive Hardware Limits Single Speed Pol Hardware Limits ScreenSelect Base Satellite Dual Speed Pol Hardware Limits ScreenPeak on Base Satellite Select Base Satellite ScreenOMACS3000 Peak on Base Satellite Screen Automated Set Software Limits Automated Set Software Limits ScreenEnter Beacon Receiver Parameters DirectionReview Parameters Enter Tracking Parameters ScreenInitialization Complete Review Parameters ScreenNormal Operational Screens Position/JogTracking Control Position/Jog ScreenTracking Summary Satellite Table Screens Track Control ScreenSatellite Table Screen Satellite Table Button Right Click OptionWorking Satellite Table Screen Satellite Table ScreenSatellite Entry Edit Working Satellite Table ScreenLogs/Alarms Satellite Table Entry Edit ScreenLog/Alarms Button Right Click Display Log ScreenAlarm Screen Alarm and Events DescriptionsOMACS3000 OMACS3000 OMACS3000 Update Table Alarm ScreenCelestrack Web Site Norad Data Set Update Software Alternate Update Satellite Table Popup WindowUpdate Software Button OMACS3000

OMACS3000 specifications

Andrew OMACS3000 is a highly advanced multi-functional automation and control system designed to streamline operations in various industries, including manufacturing, utilities, and logistics. At its core, the OMACS3000 integrates cutting-edge technologies to enhance efficiency, improve precision, and facilitate real-time data monitoring.

One of the main features of the OMACS3000 is its modular architecture. This design allows users to customize the system according to specific operational needs, enabling them to scale up or down as necessary. The system can support a wide array of inputs and outputs, making it adaptable for different types of machinery and processes. The modular approach not only allows for easy upgrades but also minimizes downtime during maintenance or system changes.

Another significant characteristic of the OMACS3000 is its use of smart sensors and IoT connectivity. The system is equipped with advanced sensors that monitor various parameters such as temperature, pressure, and flow rates in real time. By leveraging IoT technology, the OMACS3000 can transmit data to a centralized management platform, allowing for in-depth analysis and streamlined decision-making. This connectivity facilitates predictive maintenance, reducing the risk of unexpected failures and optimizing maintenance schedules.

The OMACS3000 is also designed with user-friendly interfaces, featuring intuitive dashboards that provide operators with easy access to critical information. These dashboards allow users to track performance metrics, set alerts for abnormal conditions, and visualize data trends. By prioritizing user experience, the OMACS3000 empowers operators to make informed decisions quickly, thus improving overall operational efficiency.

In terms of security, the OMACS3000 incorporates robust cybersecurity measures to protect sensitive data and prevent unauthorized access. Advanced encryption protocols and user authentication mechanisms are employed to safeguard the system against potential threats, ensuring the integrity of operations.

Finally, the OMACS3000 is built to comply with international standards for safety and quality, making it suitable for global markets. Its adaptability, coupled with its comprehensive features and advanced technologies, positions the OMACS3000 as a leader in the automation and control systems landscape, paving the way for the future of efficient and reliable industrial operations.