Andrew OMACS3000 manual Verify Az and El Hardware Limits, Verify Jog Direction Screen

Page 22

11-APR-06

Rev E

OMACS3000

The operator must select the buttons to move in each of the directions allowed by the screen. If the pol drive is not installed, only East, West, Up and Down jog directions will be displayed. The observer must let the operator know if the direction commanded by the operator is the same that the antenna actually moves. If any direction movement is incorrect, initialization must stop and the antenna wiring must be corrected before restarting the initialization. If the direction selected moves as indicated (for example, Az West increments the Az displayed at the top), the operator should select the appropriate check box to set the check mark. Once all directions have been verified, the operator should enter Next to go to the next step.

Figure 14: Verify Jog Direction Screen

Verify Az and El Hardware Limits

This step in the Initialization Wizard also requires an antenna observer who is in contact with the antenna controller operator. The observer is needed to request emergency stop from the operator if any wires or wire harnesses become entangled as the antenna moves or the antenna moves beyond its physical limits.

WARNING

The observer must be in position to stop the hardware from moving into obstructions, twisting wires, or moving beyond physical limits.

The operator moves in each of the directions allowed by the screen. If the pol drive is installed, it will be checked in later screens. The operator will jog each axis one at a time until that axis reaches the physical limit. The operator will know that the limit is reached when that direction checkbox is checked. The operator should also notice that the resolver counts (as displayed by the position status line) will discontinue counting

22 of 51

System Screens

Image 22
Contents ACS3000 Antenna Control System OMACS3000 OMACS3000 List of Figures Revision History OverviewSummary System DescriptionOMACS3000 Motherboard Limit/Status Card LIM-2 Indicators Within the LMKVS-CPUMC-2 Description Microprocessor Card MPU-17Dual VFD Motor Drive Card MD-3 Low Temperature BoardResolver To Digital Converter Card RES-2 Power/Environmental Description Beacon Interface Power/Environmental Description LMKVS-CPUAntenna Display Unit Optional System Description LMKVS-CPU IP Setup Operator’s Computer SetupJava Plug In Installation Operator’s Computer IP AddressRegional Options Setup LMKVS-CPU Admin ApplicationHome Screen System Not Initialized ACS3000 ScreensHome Screen System Initialized Home Screen Hand Held Connected Home Screen System Is InitializedSet Time/IP Home Screen Hand Held Controller ConnectedInitialization Screens Initialization EntryTest Only Password Protection Screen Initialization Entry ScreenPre-Initialization Antenna Setup Test Only Password ScreenPre-Initialization Antenna Setup Initialize Site LocationAntenna Size Polarization Drive P/N Ratio Visible Satellites ComputedVerify Jog Direction Visible Satellites Computed ScreenVerify Az and El Hardware Limits Verify Jog Direction ScreenVerify Pol Hardware Limits Single Speed Pol Drive Hardware LimitsDual Speed Pol Drive Hardware Limits Single Speed Pol Hardware Limits ScreenSelect Base Satellite Dual Speed Pol Hardware Limits ScreenPeak on Base Satellite Select Base Satellite ScreenOMACS3000 Peak on Base Satellite Screen Automated Set Software Limits Automated Set Software Limits ScreenEnter Beacon Receiver Parameters DirectionReview Parameters Enter Tracking Parameters ScreenInitialization Complete Review Parameters ScreenNormal Operational Screens Position/JogTracking Control Position/Jog ScreenTracking Summary Satellite Table Screens Track Control ScreenSatellite Table Screen Satellite Table Button Right Click OptionWorking Satellite Table Screen Satellite Table ScreenSatellite Entry Edit Working Satellite Table ScreenLogs/Alarms Satellite Table Entry Edit ScreenLog/Alarms Button Right Click Display Log ScreenAlarm Screen Alarm and Events DescriptionsOMACS3000 OMACS3000 OMACS3000 Update Table Alarm ScreenCelestrack Web Site Norad Data Set Update Software Alternate Update Satellite Table Popup WindowUpdate Software Button OMACS3000

OMACS3000 specifications

Andrew OMACS3000 is a highly advanced multi-functional automation and control system designed to streamline operations in various industries, including manufacturing, utilities, and logistics. At its core, the OMACS3000 integrates cutting-edge technologies to enhance efficiency, improve precision, and facilitate real-time data monitoring.

One of the main features of the OMACS3000 is its modular architecture. This design allows users to customize the system according to specific operational needs, enabling them to scale up or down as necessary. The system can support a wide array of inputs and outputs, making it adaptable for different types of machinery and processes. The modular approach not only allows for easy upgrades but also minimizes downtime during maintenance or system changes.

Another significant characteristic of the OMACS3000 is its use of smart sensors and IoT connectivity. The system is equipped with advanced sensors that monitor various parameters such as temperature, pressure, and flow rates in real time. By leveraging IoT technology, the OMACS3000 can transmit data to a centralized management platform, allowing for in-depth analysis and streamlined decision-making. This connectivity facilitates predictive maintenance, reducing the risk of unexpected failures and optimizing maintenance schedules.

The OMACS3000 is also designed with user-friendly interfaces, featuring intuitive dashboards that provide operators with easy access to critical information. These dashboards allow users to track performance metrics, set alerts for abnormal conditions, and visualize data trends. By prioritizing user experience, the OMACS3000 empowers operators to make informed decisions quickly, thus improving overall operational efficiency.

In terms of security, the OMACS3000 incorporates robust cybersecurity measures to protect sensitive data and prevent unauthorized access. Advanced encryption protocols and user authentication mechanisms are employed to safeguard the system against potential threats, ensuring the integrity of operations.

Finally, the OMACS3000 is built to comply with international standards for safety and quality, making it suitable for global markets. Its adaptability, coupled with its comprehensive features and advanced technologies, positions the OMACS3000 as a leader in the automation and control systems landscape, paving the way for the future of efficient and reliable industrial operations.