Andrew OMACS3000 manual

Page 43

11-APR-06

Rev E

OMACS3000

"Invalid satellite data entered for satID=nnnnn"

Operator made error in editing or adding satellite data to satellite with the Norad ID of nnnnn. The operator must correct the satellite entry.

"MCU error ON (or OFF) - Az East Hardware Limits". Az East Hardware Limits reached.

"MCU error ON (or OFF) - Az West Hardware Limits". Az West Hardware Limits reached.

"MCU error ON (or OFF) - El Up Hardware Limits". El Up Hardware Limits reached.

"MCU error ON (or OFF) - El Down Hardware Limits". El Down Hardware Limits reached.

"MCU error ON (or OFF) - Pol Clockwise Hardware Limits". Pol Clockwise Hardware Limits reached.

"MCU error ON (or OFF) - Pol Counterclockwise Hardware Limits". Pol Counterclockwise Hardware Limits reached.

"MCU error ON (or OFF) - Az East Software Limits". Az East Software Limits reached.

"MCU error ON (or OFF) - Az West Software Limits". Az West Software Limits reached.

"MCU error ON (or OFF) - El Up Software Limits". El Up Software Limits reached.

"MCU error ON (or OFF) - El Down Software Limits". El Down Software Limits reached.

"MCU error ON (or OFF) - Pol Clockwise Software Limits". Pol Clockwise Software Limits reached.

"MCU error ON (or OFF) - Pol Counterclockwise Software Limits". Pol Counterclockwise Software Limits reached.

"MCU error ON (or OFF) - Az move hardware timeout".

Az move hardware timeout. Axis has failed to reach the commanded position within the allowed time.

"MCU error ON (or OFF) - El move hardware timeout".

El move hardware timeout. Axis has failed to reach the commanded position within the allowed time.

"MCU error ON (or OFF) - Pol move hardware timeout".

Pol move hardware timeout. Axis has failed to reach the commanded position within the allowed time.

"MCU error ON (or OFF) - Az Direction".

Az Direction. Axis is moving in the opposite direction of the commanded position.

"MCU error ON (or OFF) - El Direction".

El Direction. Axis is moving in the opposite direction of the commanded position.

43 of 51

System Screens

Image 43
Contents ACS3000 Antenna Control System OMACS3000 OMACS3000 List of Figures System Description OverviewSummary Revision HistoryOMACS3000 Microprocessor Card MPU-17 Indicators Within the LMKVS-CPUMC-2 Description Motherboard Limit/Status Card LIM-2Dual VFD Motor Drive Card MD-3 Low Temperature BoardResolver To Digital Converter Card RES-2 Power/Environmental Description Beacon Interface Power/Environmental Description LMKVS-CPUAntenna Display Unit Optional System Description Operator’s Computer IP Address Operator’s Computer SetupJava Plug In Installation LMKVS-CPU IP SetupLMKVS-CPU Admin Application Regional Options SetupHome Screen System Not Initialized ACS3000 ScreensHome Screen System Initialized Home Screen System Is Initialized Home Screen Hand Held ConnectedHome Screen Hand Held Controller Connected Set Time/IPInitialization Entry Initialization ScreensInitialization Entry Screen Test Only Password Protection ScreenTest Only Password Screen Pre-Initialization Antenna SetupInitialize Site Location Pre-Initialization Antenna SetupVisible Satellites Computed Antenna Size Polarization Drive P/N RatioVisible Satellites Computed Screen Verify Jog DirectionVerify Jog Direction Screen Verify Az and El Hardware LimitsSingle Speed Pol Drive Hardware Limits Verify Pol Hardware LimitsSingle Speed Pol Hardware Limits Screen Dual Speed Pol Drive Hardware LimitsDual Speed Pol Hardware Limits Screen Select Base SatelliteSelect Base Satellite Screen Peak on Base SatelliteOMACS3000 Peak on Base Satellite Screen Automated Set Software Limits Screen Automated Set Software LimitsDirection Enter Beacon Receiver ParametersEnter Tracking Parameters Screen Review ParametersReview Parameters Screen Initialization CompletePosition/Jog Normal Operational ScreensPosition/Jog Screen Tracking ControlTracking Summary Track Control Screen Satellite Table ScreensSatellite Table Button Right Click Option Satellite Table ScreenSatellite Table Screen Working Satellite Table ScreenWorking Satellite Table Screen Satellite Entry EditSatellite Table Entry Edit Screen Logs/AlarmsLog Screen Log/Alarms Button Right Click DisplayAlarm and Events Descriptions Alarm ScreenOMACS3000 OMACS3000 OMACS3000 Alarm Screen Update TableCelestrack Web Site Norad Data Set Alternate Update Satellite Table Popup Window Update SoftwareUpdate Software Button OMACS3000

OMACS3000 specifications

Andrew OMACS3000 is a highly advanced multi-functional automation and control system designed to streamline operations in various industries, including manufacturing, utilities, and logistics. At its core, the OMACS3000 integrates cutting-edge technologies to enhance efficiency, improve precision, and facilitate real-time data monitoring.

One of the main features of the OMACS3000 is its modular architecture. This design allows users to customize the system according to specific operational needs, enabling them to scale up or down as necessary. The system can support a wide array of inputs and outputs, making it adaptable for different types of machinery and processes. The modular approach not only allows for easy upgrades but also minimizes downtime during maintenance or system changes.

Another significant characteristic of the OMACS3000 is its use of smart sensors and IoT connectivity. The system is equipped with advanced sensors that monitor various parameters such as temperature, pressure, and flow rates in real time. By leveraging IoT technology, the OMACS3000 can transmit data to a centralized management platform, allowing for in-depth analysis and streamlined decision-making. This connectivity facilitates predictive maintenance, reducing the risk of unexpected failures and optimizing maintenance schedules.

The OMACS3000 is also designed with user-friendly interfaces, featuring intuitive dashboards that provide operators with easy access to critical information. These dashboards allow users to track performance metrics, set alerts for abnormal conditions, and visualize data trends. By prioritizing user experience, the OMACS3000 empowers operators to make informed decisions quickly, thus improving overall operational efficiency.

In terms of security, the OMACS3000 incorporates robust cybersecurity measures to protect sensitive data and prevent unauthorized access. Advanced encryption protocols and user authentication mechanisms are employed to safeguard the system against potential threats, ensuring the integrity of operations.

Finally, the OMACS3000 is built to comply with international standards for safety and quality, making it suitable for global markets. Its adaptability, coupled with its comprehensive features and advanced technologies, positions the OMACS3000 as a leader in the automation and control systems landscape, paving the way for the future of efficient and reliable industrial operations.