Andrew OMACS3000 manual Normal Operational Screens, Position/Jog

Page 33

11-APR-06

Rev E

OMACS3000

Figure 24: Initialization Complete Screen

Normal Operational Screens

The rest of the screens displayed and discussed in this section are available only after all the setup and initialization processes have been completed correctly. The following screens will be in use the majority of the time.

Position/Jog

This operational screen (see Figure 25) allows the operator to move the antenna to the desired position or jog in a desired direction. The speed selection affects only the speed at which jogging is performed. The move command will always move at the fastest speed allowed according the distance of the move defined. The jog will jog at the selected speed.

Track speed is the slower speed and should be used when the operator is near a target and wishes to peak up on the target by jogging and checking the beacon values for peaks. Slew speed is used when the operator wishes to jog the antenna at a faster rate in order to cover more distance quickly. The Stop command is used to terminate a move in progress. The Stop command is not necessary when the antenna is jogged - merely releasing the jog button will stop the jog. If the jog speed is set to slew mode, when the operator holds down a jog button, the antenna will move at a slow rate for the first four seconds of the move then switch to the fast rate for the remainder of the jog. If the track speed is selected, the slow rate will be used for the whole term of the jog. The operator can select to jog in only one direction at a time. However, if the operator selects a move request that changes more then one axis, the antenna will be moved in all axes requiring a move at the same time.

The position/jog screen also provides for special purpose functions to allow the operator to reset and clear the MCU, save the current position as the peaked position for the base satellite, or copy the position log to a local file. The MCU reset is needed to clear MCU latched errors. The MCU latched errors are direction

33 of 51

System Screens

Image 33
Contents ACS3000 Antenna Control System OMACS3000 OMACS3000 List of Figures Summary OverviewRevision History System DescriptionOMACS3000 MC-2 Description Indicators Within the LMKVS-CPUMotherboard Limit/Status Card LIM-2 Microprocessor Card MPU-17Low Temperature Board Dual VFD Motor Drive Card MD-3Resolver To Digital Converter Card RES-2 Power/Environmental Description LMKVS-CPU Power/Environmental Description Beacon InterfaceAntenna Display Unit Optional System Description Java Plug In Installation Operator’s Computer SetupLMKVS-CPU IP Setup Operator’s Computer IP AddressLMKVS-CPU Admin Application Regional Options SetupACS3000 Screens Home Screen System Not InitializedHome Screen System Initialized Home Screen System Is Initialized Home Screen Hand Held ConnectedHome Screen Hand Held Controller Connected Set Time/IPInitialization Entry Initialization ScreensInitialization Entry Screen Test Only Password Protection ScreenTest Only Password Screen Pre-Initialization Antenna SetupInitialize Site Location Pre-Initialization Antenna SetupVisible Satellites Computed Antenna Size Polarization Drive P/N RatioVisible Satellites Computed Screen Verify Jog DirectionVerify Jog Direction Screen Verify Az and El Hardware LimitsSingle Speed Pol Drive Hardware Limits Verify Pol Hardware LimitsSingle Speed Pol Hardware Limits Screen Dual Speed Pol Drive Hardware LimitsDual Speed Pol Hardware Limits Screen Select Base SatelliteSelect Base Satellite Screen Peak on Base SatelliteOMACS3000 Peak on Base Satellite Screen Automated Set Software Limits Screen Automated Set Software LimitsDirection Enter Beacon Receiver ParametersEnter Tracking Parameters Screen Review ParametersReview Parameters Screen Initialization CompletePosition/Jog Normal Operational ScreensPosition/Jog Screen Tracking ControlTracking Summary Track Control Screen Satellite Table ScreensSatellite Table Button Right Click Option Satellite Table ScreenSatellite Table Screen Working Satellite Table ScreenWorking Satellite Table Screen Satellite Entry EditSatellite Table Entry Edit Screen Logs/AlarmsLog Screen Log/Alarms Button Right Click DisplayAlarm and Events Descriptions Alarm ScreenOMACS3000 OMACS3000 OMACS3000 Alarm Screen Update TableCelestrack Web Site Norad Data Set Alternate Update Satellite Table Popup Window Update SoftwareUpdate Software Button OMACS3000

OMACS3000 specifications

Andrew OMACS3000 is a highly advanced multi-functional automation and control system designed to streamline operations in various industries, including manufacturing, utilities, and logistics. At its core, the OMACS3000 integrates cutting-edge technologies to enhance efficiency, improve precision, and facilitate real-time data monitoring.

One of the main features of the OMACS3000 is its modular architecture. This design allows users to customize the system according to specific operational needs, enabling them to scale up or down as necessary. The system can support a wide array of inputs and outputs, making it adaptable for different types of machinery and processes. The modular approach not only allows for easy upgrades but also minimizes downtime during maintenance or system changes.

Another significant characteristic of the OMACS3000 is its use of smart sensors and IoT connectivity. The system is equipped with advanced sensors that monitor various parameters such as temperature, pressure, and flow rates in real time. By leveraging IoT technology, the OMACS3000 can transmit data to a centralized management platform, allowing for in-depth analysis and streamlined decision-making. This connectivity facilitates predictive maintenance, reducing the risk of unexpected failures and optimizing maintenance schedules.

The OMACS3000 is also designed with user-friendly interfaces, featuring intuitive dashboards that provide operators with easy access to critical information. These dashboards allow users to track performance metrics, set alerts for abnormal conditions, and visualize data trends. By prioritizing user experience, the OMACS3000 empowers operators to make informed decisions quickly, thus improving overall operational efficiency.

In terms of security, the OMACS3000 incorporates robust cybersecurity measures to protect sensitive data and prevent unauthorized access. Advanced encryption protocols and user authentication mechanisms are employed to safeguard the system against potential threats, ensuring the integrity of operations.

Finally, the OMACS3000 is built to comply with international standards for safety and quality, making it suitable for global markets. Its adaptability, coupled with its comprehensive features and advanced technologies, positions the OMACS3000 as a leader in the automation and control systems landscape, paving the way for the future of efficient and reliable industrial operations.