Nuvo NV-E6DXS-DC, NV-E6DMS-DC manual Response Same response as for *ZxxSETSRCR

Page 27

*********************************************************************************

COMMAND: *ZxxMTOFF<CR> zone xx MUTE OFF (returns zone output to currently connected source at previous volume setting).

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ZxxBASSyyy<CR> zone xx BASS EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10. RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile BASS setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxTREByyy<CR> zone xx TREBLE EQ with yyy = EQ level, dB, 12 to +0 (flat) to +12 in 2 dB increments.

USE LEAD “0” IN TENS PLACE FOR VALUE LESS THAN 10. RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile TREBLE setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxGRPON<CR> zone xx SOURCE GROUP ON.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxGRPOFF<CR> zone xx SOURCE GROUP OFF.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the will override the non-volatile GROUP setting (set from keypad) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxVRSTON<CR> zone xx VOLUME RESET ON.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxVRSTOFF<CR> zone xx VOLUME RESET OFF.

RESPONSE: Same response as for *ZxxSETSR<CR>

NOTE: sending this command to the E6D will set override (lock out KEYPAD non-address DIP switches) for this zone until power is cycled.

*********************************************************************************

COMMAND: *ZxxLKON<CR> zone xx KEYPAD LOCK ON This will INHIBIT ANY keypad control input on the zone. This is the same as activating the Parental lock control at a keypad by holding down a SOURCE key for three seconds).

RESPONSE: #ZxxLKON<CR>6

26

Image 27
Contents Page English Importantes Instructions DE Securite Dure EN Heures PAR JourNV-E6DM2 IntroductionEssentia Front Panel Keypad FeaturesEssentia D Essentia Back PanelSetup LRC1 Learning Remote ControlInstalling the Essentia System in Your Home PrewireStep-by-Step Crimping Instructions II. Terminating Speaker Wire II. Installing the Essentia AmplifierVI. Connecting the IR Emitters IV. Connecting the EZ Port to the Essentia amplifierVIII. Installing the Essentia Keypads VII. Expanding Essentia to 12 ZonesData Link Cable Source Link Cable EQ Control and Source Grouping IX. Keypad Zone SettingsVolume Reset All On/Party ModeZone Variable Lineout Using the Fixed and Variable LineoutsSpeaker Zone Fixed LineoutXII. NV-MI1 Mute Interface Adapter XI. The NV-LRC1 IR Remote ControlNuVo System zone speakers XIII. NV-LSA40 Local Source AmplifierLSA40PD Front Essentia D XV. NV-LSI12 Local Source InterruptEssentia Amplifier XVI. NV-P2100 200 Watt Auxiliary AmplifierRS232 Interface NV-P2100 AmplifierSymptom Probable Cause Remedy TroubleshootingZones 1-6 Power Amplifier Outputs Zone Trigger Outputs SpecificationsRules of Protocol Nuvo POWER-ON StateAddendum DB9M Port PinoutsCOMMAND/RESPONSE Descriptions Response #ALLV+CR CommandResponse Response #ALLOFFCRResponse #ALLHLD-CR Response #ALLV-CRResponse Same response as for *ZxxSETSRCR #ZxxLKOFFCR ESS513