Nuvo NV-E6DMS-DC, NV-E6DXS-DC manual Response #ALLV-CR, Response #ALLHLD-CR

Page 26

Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLV-<CR>Ramp ALL zones DOWN at a 10 dB/second rate in 1 dB steps.

RESPONSE: #ALLV-<CR>

The ramp action will be cancelled when all zones reach MINIMUM (OFF) volume, or when an *ALLHLD<CR> Command is received. Note that to stop the ramp with this command before the minimum volume, one reference zone must be periodically polled with a *ZxxCONSR<CR> Command to determine when the desired volume point has been reached. Note that ramps in different zones may start at different levels and will all ramp at the same rate.

*********************************************************************************

COMMAND: *ALLHLD<CR> Stops ramp action initiated by *ALLV+<CR> Or *ALLV-<CR>

RESPONSE: #ALLHLD-<CR>

This results in a HOLD of the level at time of command receipt.

*********************************************************************************

COMMAND: *ALLMON<CR> ALL MUTE ON.

RESPONSE: # ALLMON<CR>

*********************************************************************************

COMMAND: *ALLMOFF<CR> ALL MUTE OFF.

RESPONSE: #ALLMOFF<CR>

********************************************************************************

COMMAND: *ZxxSRCp<CR> Switch zone xx to SOURCE p ( 1 to 6).

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ZxxVOLyy<CR> Set volume of zone xx to level yy below max in dB from 0 to 78 dB (include lead 0 for all single-digit values).

RESPONSE: Same response as for *ZxxCONSR<CR>

*********************************************************************************

COMMAND: *ZxxVOL+<CR> STARTS zone xx volume ramp UP at the rate of +10 dB per second in +1 dB steps. (This is the same as holding VOLUME UP key on a KEYPAD for 1 second).

RESPONSE: Same response as for *ZxxCONSR<CR>, updated 10 times per second.

*********************************************************************************

COMMAND: *ZxxVOL-<CR>STARTS zone xx volume ramp DOWN at the rate of -10 dB per second in -1 dB steps. (This is the same as holding VOLUME UP key on a KEYPAD for 1 second).

RESPONSE: Same response as for *ZxxCONSR<CR>, updated 10 times per second.

*********************************************************************************

COMMAND: *ZxxVHLD<CR> STOPS zone xx volume ramp initiated by *ZxxVOL++<CR> or *ZxxVOL--<CR>commands. This results in a HOLD of the level at time of command receipt.

RESPONSE: #ZxxVHLD<CR>

*********************************************************************************

COMMAND: *ZxxMTON<CR> zone xx MUTE ON (mutes currently connected source)

RESPONSE: Same response as for *ZxxCONSR<CR>

25

Image 26
Contents Page English Dure EN Heures PAR Jour Importantes Instructions DE SecuriteIntroduction NV-E6DM2Keypad Features Essentia Front PanelEssentia Back Panel Essentia DLRC1 Learning Remote Control SetupStep-by-Step Crimping Instructions Installing the Essentia System in Your HomePrewire II. Installing the Essentia Amplifier II. Terminating Speaker WireIV. Connecting the EZ Port to the Essentia amplifier VI. Connecting the IR EmittersData Link Cable Source Link Cable VIII. Installing the Essentia KeypadsVII. Expanding Essentia to 12 Zones IX. Keypad Zone Settings EQ Control and Source GroupingAll On/Party Mode Volume ResetUsing the Fixed and Variable Lineouts Zone Variable LineoutZone Fixed Lineout SpeakerXI. The NV-LRC1 IR Remote Control XII. NV-MI1 Mute Interface AdapterXIII. NV-LSA40 Local Source Amplifier NuVo System zone speakersLSA40PD Front XV. NV-LSI12 Local Source Interrupt Essentia DNV-P2100 Amplifier XVI. NV-P2100 200 Watt Auxiliary AmplifierRS232 Interface Essentia AmplifierTroubleshooting Symptom Probable Cause RemedySpecifications Zones 1-6 Power Amplifier Outputs Zone Trigger OutputsDB9M Port Pinouts Nuvo POWER-ON StateAddendum Rules of ProtocolCOMMAND/RESPONSE Descriptions Response #ALLOFFCR CommandResponse Response #ALLV+CRResponse #ALLV-CR Response #ALLHLD-CRResponse Same response as for *ZxxSETSRCR #ZxxLKOFFCR ESS513