Nuvo NV-E6DXS-DC, NV-E6DMS-DC Addendum, DB9M Port Pinouts, Rules of Protocol, Nuvo POWER-ON State

Page 23

Addendum

Control Interface Description Document for the Nuvo E6D Main Unit

Revision E (for Nuvo E6D Mark II systems only) June 8, 2006

DB9M PORT PINOUTS:

Nuvo Transmit to System Controller on pin 2.

 

Nuvo Receive from System Controller on pin 3.

 

Ground on pin 5.

SERIAL PORT PARAMETERS: RS232, RTS/CTS or software flow control (XON/XOFF) NOT required, 9600 baud, 8N1 protocol.

RULES OF PROTOCOL:

(1)For alpha ASCII characters, always use UPPER CASE. In this document, actual characters in a string are presented in BOLD type.

(2)All numerical fields are coded as ASCII digit characters.

(3)Each Command string is STARTED with an ASCII “*” character and terminated by a <CR> character (0D hexadecimal). Each response string issued by the E6D will START with an ASCII “#” and be terminated with a <CR> character (0D hexadecimal).

(4)If a command has an error in it (does not adhere to exact command syntax), the E6D will respond with a “#?<CR>” string.

(5)Whenever queuing multiple commands to the E6D, the host program should pause for 50 milliseconds between commands to prevent buffer overruns.

NUVO POWER-ON STATE:

(1)Each zone is OFF until ON command is received.

(2)Each zone's ZoneSet status will be as set by the special key combination settings as detailed in the owner's manual. If no keypad is connected with a given zone address, then ZoneSet will default to:

A. OR0 (No override)

B.BASS+0 (Bass FLAT)

C.TREB+0 (Treble FLAT)

D.GRP0 (SOURCE GROUPING OFF)

E.VRST1 (VOLUME RESET TO 50 dB ON)

If these zone settings are overridden by the commands which follow in this document, the overridden values will reset to the default values above upon cycling power on the Main Unit.

(3)For the first four seconds after power-on, a series of non-control related characters will be issued at a wide range of baud rates. These are necessary queries to a program that may be running on a connected PC for the purpose of Firmware field upgrades. They should be ignored by the host control system.

NON-VOLATILE COMMANDS AND ASSOCIATED RESPONSES With the exception of commands associated with setting the IR carrier frequency, the effect of all commands is non-permanent; i.e. when power is cycled on the main unit, it will return to default values. The commands that are an exception to this rule follow in this section.

*********************************************************************************

COMMAND: *IRSETSR<CR> Reads status of SOURCE IR carrier frequency settings.

RESPONSE: #IRSET:aa,bb,cc,dd,ee,ff<CR> where:

aa= IR carrier frequency of SOURCE 1 ("38" or "56")

bb= carrier frequency of SOURCE 2 ("38" or "56")

cc= carrier frequency of SOURCE 3 ("38" or "56")

dd= carrier frequency of SOURCE 4 ("38" or "56")

ee= carrier frequency of SOURCE 5 ("38" or "56")

ff= carrier frequency of SOURCE 6 ("38" or "56")

22

Image 23
Contents Page English Importantes Instructions DE Securite Dure EN Heures PAR JourNV-E6DM2 IntroductionEssentia Front Panel Keypad FeaturesEssentia D Essentia Back PanelSetup LRC1 Learning Remote ControlStep-by-Step Crimping Instructions Installing the Essentia System in Your HomePrewire II. Terminating Speaker Wire II. Installing the Essentia AmplifierVI. Connecting the IR Emitters IV. Connecting the EZ Port to the Essentia amplifierData Link Cable Source Link Cable VIII. Installing the Essentia KeypadsVII. Expanding Essentia to 12 Zones EQ Control and Source Grouping IX. Keypad Zone SettingsVolume Reset All On/Party ModeZone Variable Lineout Using the Fixed and Variable LineoutsSpeaker Zone Fixed LineoutXII. NV-MI1 Mute Interface Adapter XI. The NV-LRC1 IR Remote ControlNuVo System zone speakers XIII. NV-LSA40 Local Source AmplifierLSA40PD Front Essentia D XV. NV-LSI12 Local Source InterruptEssentia Amplifier XVI. NV-P2100 200 Watt Auxiliary AmplifierRS232 Interface NV-P2100 AmplifierSymptom Probable Cause Remedy TroubleshootingZones 1-6 Power Amplifier Outputs Zone Trigger Outputs SpecificationsRules of Protocol Nuvo POWER-ON StateAddendum DB9M Port PinoutsCOMMAND/RESPONSE Descriptions Response #ALLV+CR CommandResponse Response #ALLOFFCRResponse #ALLHLD-CR Response #ALLV-CRResponse Same response as for *ZxxSETSRCR #ZxxLKOFFCR ESS513