Nuvo NV-E6DMS-DC, NV-E6DXS-DC manual COMMAND/RESPONSE Descriptions

Page 24

NOTE: the Main Unit ships with the carrier frequency DEFAULT setting of 38 KHz for all six sources.

*********************************************************************************

COMMAND: *IRSETDF<CR> Restores DEFAULT SOURCE IR carrier frequency settings (38 KHz for all six sources).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND: *SxIR56SET<CR> - sets SOURCE x to 56 KHz IR repeat carrier (x is 1 to 6).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND: *SxIR38SET<CR> - sets SOURCE x to 38 KHz IR repeat carrier (x is 1 to 6).

RESPONSE: Same response as for #IRSETSR<CR>

*********************************************************************************

COMMAND/RESPONSE DESCRIPTIONS.

NOTE zone number field xx should ALWAYS include a lead zero (“0”) for zone numbers less than 10.

COMMAND: *ZxxCONSR<CR> - Connect STATUS REQUEST where xx is zone # from 1 to 12.

RESPONSE: #ZxxPWRppp,SRCs,GRPt,VOL-yy,Pzzz<CR>-ppp = “ON” (2 characters) or “OFF” (3 characters)

The remaining fields are not included in the response if ppp is “OFF”:

-s = SOURCE NUMBER 1 to 6

-q = 0 if SOURCE GROUP is ON 1if SOURCE GROUP is OFF

-yy = level below max in dB: -00 to -78 dB (include lead 0 for all single-digit values)

-yy = “MT” if in MUTE state

-yy = “XM” if external MUTE is being held active

-zzz = “MST” if this zone is PARTY MASTER -zzz = “SLV” if this zone is SLAVED to a

PARTY MASTER in another zone

-zzz = “OFF” if this zone is under LOCAL CONTROL only (either there is no party master, or this zone has been manually

overridden)

This response will also be issued in response to pressing the ON/OFF, VOLUME, or SOURCE keys on a KEYPAD. NOTE the response will be issued if a SOURCE key is pressed on a zone that is powered OFF even though the key press has no effect on the system. It will be output at every increment during a volume ramp initiated by HOLDING a VOLUME UP or VOLUME DOWN key on a keypad. It will also be issued at every increment of a volume ramp commanded by the *ZxxVOL+<CR> and *ZxxVOL-<CR>commands (see below).

The MUTE value will be asserted if a *ZxMTON<CR> command has been received, OR if the volume is run all the way to the lowest possible point (volume off). An active EXTERNAL

23

Image 24
Contents Page English Dure EN Heures PAR Jour Importantes Instructions DE SecuriteIntroduction NV-E6DM2Keypad Features Essentia Front PanelEssentia Back Panel Essentia DLRC1 Learning Remote Control SetupInstalling the Essentia System in Your Home PrewireStep-by-Step Crimping Instructions II. Installing the Essentia Amplifier II. Terminating Speaker WireIV. Connecting the EZ Port to the Essentia amplifier VI. Connecting the IR EmittersVIII. Installing the Essentia Keypads VII. Expanding Essentia to 12 ZonesData Link Cable Source Link Cable IX. Keypad Zone Settings EQ Control and Source GroupingAll On/Party Mode Volume ResetUsing the Fixed and Variable Lineouts Zone Variable LineoutZone Fixed Lineout SpeakerXI. The NV-LRC1 IR Remote Control XII. NV-MI1 Mute Interface AdapterXIII. NV-LSA40 Local Source Amplifier NuVo System zone speakersLSA40PD Front XV. NV-LSI12 Local Source Interrupt Essentia DXVI. NV-P2100 200 Watt Auxiliary Amplifier RS232 InterfaceNV-P2100 Amplifier Essentia AmplifierTroubleshooting Symptom Probable Cause RemedySpecifications Zones 1-6 Power Amplifier Outputs Zone Trigger OutputsNuvo POWER-ON State AddendumDB9M Port Pinouts Rules of ProtocolCOMMAND/RESPONSE Descriptions Command ResponseResponse #ALLOFFCR Response #ALLV+CRResponse #ALLV-CR Response #ALLHLD-CRResponse Same response as for *ZxxSETSRCR #ZxxLKOFFCR ESS513