Frymaster MF90 Series manual Changing Filter Paper

Page 13

4.4 Changing Filter Paper (cont.)

Remove and replace the paper as follows:

1.Remove filter cover.

2.Open the locking clips of the hold- down ring and lift the ring out of the filter tank.

3.Roll both ends of the top filter paper into the center, making sure no sediment falls out, and discard. Remove the second sheet of filter paper and retain for re- use.

4-3

Image 13
Contents MF90 Series Page Table of Contents Ordering Parts Service InformationAfter Purchase Safety InformationGeneral Rating Plate Pre-InstallationUnpacking the Filter System Assembling The Filter System Filter Paper ConfigurationFilter Paper Configuration Wand Filter Preparation Filtering ToolsChanging Filter Paper Changing Filter Paper Changing Filter Paper Unit Operation Unit Operation Unit Operation Unit Operation Each Filter Use Weekly Daily- Close Of BusinessPlugged Lines Operating ProblemsTroubleshooting Flowcharts Filter Pump Fails To Pump Oil Rate Of Oil Return Slowing Blockage Between Filter Pan and Flex-Hose Valve MF90 Filter Wiring AU Wiring DiagramsMF-90/65, U and AU Configuration Dean Portable MICRO-FLO OIL Filtration Systems Parts ListComponent MF-90/65, U and AU Configuration MF-90/80, 80-LP, 110, 126, 160 and 172 Series, U and AU Configurations110 Series Only Component Tubing Assembly 80, 80-LP, 126 and 160 Series Service Hotline